Unit configuration

AquaMax Eco Titanium 30000/50000
 D
 E
Position
Description
1
1
Pump casing
− The position of the outlet can be changed by fitting the pump casing rotated through 90°.
2
2
Stand
− Ensures secure and stable positioning of the pump.
− Can be firmly bolted to the ground.
3
3
Outlet (pressure socket)
− AquaMax Eco Titanium 30000: ∅ 63 mm (DN 63)
− AquaMax Eco Titanium 50000: ∅ 75 mm (DN 75)
4
4
Inlet (suction socket)
− AquaMax Eco Titanium 30000: ∅ 63 mm (DN 63)
− AquaMax Eco Titanium 50000: ∅ 75 mm (DN 75)
EGC
EGC
EGC connection
IN/OUT
IN/OUT
− Connection for Eco Control or for integration in an EGC network.
Important: Moisture at the connections can damage the pump.
− Only remove the protection caps for connecting the Connection Cable EGC lines or terminal resistor.
− Ensure that the rubber seals are clean and fit exactly.
− Replace damaged rubber seals.
Installation
The pump can be installed submerged and is also suitable for dry installation. The Eco Control is only suitable for dry
installation and offers several fastening options.
The use of the pump is only permitted with observance of the specified water quality. (→ Water quality)
• Pool water or salt water can impair the appearance of the unit. Such impairments are excluded from the guarantee.

Submerged installation

W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
• Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
• Isolate the device (disconnect from the power supply) before carrying out any work on it.
Eco Control
It can be fastened to the wall or ground. (→ Operating instructions Eco Control)
N O T E
Eco Control is destroyed if it immersed in water or other liquids.
• Never submerse the control unit in water or other liquids.
• Do not fasten the control unit to the pump handle if the pump is to be installed submerged in the water.
Pump
W A R N I N G
The impeller unit rotates very fast. Severe injuries by amputation of limbs possible.
• Place the pump in a pump chamber and screw the contact guard (accessory, article No. AquaMax Eco Tita-
nium 30000: 48597, AquaMax Eco Titanium 50000: 43329) onto the suction socket.
• Place the pump in a pump chamber and protect the pump chamber against unauthorised access (use a
padlock or screws to secure the access).