XA01551F-A

Notes on the structure

46
Extract from the extended order code
Device type
FMR60, FMR62, FMR67
Basic specifications
Position 1, 2 (Approval)
Selected option
1) 2)
FMR6x
BG
3)
BH
1) 4)
IG
5)
IH
1)
Combination with Position 4 (Display, Operation) = L or M in connection with Position 3
(Power Supply, Output) = A is not allowed.
2)
The designation changes in connection with Position 4 (Display, Operation) = L or M and Position 3
(Power Supply, Output) = B, C, K, L: II 3 G Ex ec [ia Ga] IIC T6 Gc
3)
The designation changes in connection with Position 4 (Display, Operation) = L or M:
II 3 G Ex ic [ia Ga] IIC T6 Gc
4)
The designation changes in connection with Position 4 (Display, Operation) = L or M and Position 3
(Power Supply, Output) = B, C, K, L: Ex ec [ia Ga] IIC T6 Gc
5)
The designation changes in connection with Position 4 (Display, Operation) = L or M:
Ex ic [ia Ga] IIC T6 Gc
Position 5 (Housing)
Selected option
1)
FMR6x
A
C
FMR62
B
FMR67
1)
Only in connection with Position 1, 2 (Approval) = BH or IH
Position 7, 8 (Antenna)
Selected option
FMR60
GA
FMR62
GE
GF
GM
GN
FMR67
GA
GP
Micropilot FMR60, FMR62, FMR67
Description
ATEX II 3 G Ex ec IIC T6 Gc
ATEX II 3 G Ex ic IIC T6 Gc
IECEx Ex ec IIC T6 Gc
IECEx Ex ic IIC T6 Gc
Description
GT19 dual compartment, plastic PBT
GT20 dual compartment, Alu, coated
GT18 dual compartment, 316L
Description
Drip-off, PTFE DN50
Integrated, PEEK, 3/4"
Integrated, PEEK, 1-1/2"
PTFE cladded flush mount DN50
PTFE cladded flush mount DN80
Drip-off, PTFE DN50
PTFE flush mount DN80