3.2
Routing the USB connection out
(Option)
•
Route the USB connection out, if provided. To do so, proceed as
described in the instructions included with this extension.
3.3
Connecting the plug-type connections to the connecting cable
Danger through incorrectly dimensioned connection cables. The Pumpfix/Ecolift is only designed for operation
with the enclosed connection cables (or equivalent). If in doubt, consult the manufacturer / supplier.
Beware of the risk through electric current if a plug is opened without authorisation during operation e.g.
through children. The attachment nuts on the plug must be tightened firmly so that they cannot be opened by
children.
Gap <32> for the plug-type connection with a plug for
– the wastewater pump 3-4 mm (3 Nm)
– Level sensor and motor of the backwater flap 1-2 mm (1 Nm)
Gap <32> for the cable duct to the plug 1-2 mm (1 Nm)
Installation
38 / 168
fig. [7]
32
fig. [8]
2017/01