VDV-507 | ENGLISH
Activating monitor / switching between additional cameras
Using the monitor button (2), you can monitor the entrance area at any
time without waiting for someone to press the bell push. Pressing the
monitor button a second time switches off the monitor.
NOTE: If an additional camera is connected (or multiple external units),
it can also be activated using the monitor button. Pressing the monitor
button once activates the camera of the external unit, pressing it a
second time switches to the first additional camera, and pressing it a
third time switches to the second additional camera. Once you flipped
through all the cameras the image from the first camera is shown again.
ON
The monitor can only be switched off by pressing the voice button twice
N
or waiting approximately 60 seconds for the system to automatically
EUR
return to standby mode.
N
SETTINGS
Monitor settings (brightness, contrast, colour and mode)
The 7" monitor has an On Screen Display (OSD), which can be called
via the menu button (13) when the monitor is active. Each press of the
menu button highlights the next option in the OSD. The „+" and „-"
buttons (11 + 12) can be used to adjust the relevant values. If a button
GB
has not been pressed for 5 seconds, the OSD switches off automatically
and the set values are saved.
The following settings can be made:
Brightness
To adjust the brightness of the monitor to the local conditions, call
the menu via the menu button. Use the „+" button to increase the
brightness and the „-" button to decrease the brightness.
Contrast
To adjust the contrast of the monitor, call the OSD with the menu button
and press the menu button again. The „Contrast" item should now be
highlighted in the OSD and the contrast can be set via the „+" and „-"
buttons.
Saturation
To adjust the saturation of the monitor, call the OSD with the menu
button and press the menu button again twice. The „Saturation" item
should now be highlighted in the OSD and the saturation can be set via
the „+" and „-" buttons.
Audio
This menu item is not relevant for this system.
VDV-507_I-Manual_210x240_Fin6.indd 16
Reset
This item in the OSD can be used to reset the monitor to the factory
settings.
To reset the monitor, call the OSD with the menu button and press
the menu button again five times. The „Reset" item should now be
highlighted. Press the „+" button once to perform a reset. The OSD
immediately disappears and the factory settings are restored.
Exit
The OSD can be exited via this item. When „Exit" is highlighted in the
OSD, press the „+" button once to exit the OSD.
TECHNICAL DATA
Operating voltage:
15 V DC
Power consumption:
270 ± 50 mA
Temperature range:
0 to +50°C
Maximum air humidity:
85%
Screen size:
178mm (7'')
Monitor resolution:
1024x600
Dimensions:
220 x 160 x 28 mm (wxhxd)
NOTES
The functionality of the unit can be affected by the influence of strong
static, electrical or high frequency fields (discharging, mobile phones,
radios, microwaves).
Cleaning and maintenance
Always disconnect mains powered units from the mains supply before
cleaning (disconnect the plug). The unit housing can be cleaned using
a soapy soft cloth. Do not use any abrasive materials or chemicals.
Remove dust build-up from ventilation slits using a brush and clean up
using a vacuum cleaner. Do not hold the vacuum cleaner nozzle directly
against the unit.
SAFETY NOTES
The warranty will be null and void in case of damages arising from
violations of these operating instructions. We are not liable for
consequential damages!
16
21.01.16 11:43