Product Manual Ring Wall STJ
2.5 Sauna heater controls
2.5.1 Timer switch
The sauna heater is controlled by operating a 12-hour timer with three operating zones. The timer is set by twisting the knob
clockwise until the desired operating zone is reached. When operating, the timer gradually travels counter-clockwise towards
the zero position.
1. 0 position. The sauna heater is not on.
2. Operating zone 1–3 hours. Set on this zone, the sauna
heater heats up at full power while the sauna thermostat
controls the temperature.
3. Preset zone 1–9 hours. Set on this zone, the sauna heater
can be preset to turn on after a certain period of time. The
heating elements will not heat up when the timer is within
this zone.
Before turning the sauna heater on, make sure the sauna room
is suitable for taking a sauna bath.
The timer operates better if it is first turned further than the desired time
and then turned back to the desired time. If the switch has not travelled
back to 0 position after finishing bathing, turn it to 0 manually.
2.5.2 Thermostat
The thermostat knob is next to the timer knob. The further
right (clockwise) the timer is switched, the higher the
temperature will rise in the sauna room. The best way to find
the ideal temperature is to first turn the thermostat fully on
the right and let the temperature rise to the desired temperature.
Subsequently, turn the thermostat knob slowly counter-clockwise
until you hear a gentle clicking sound. If you want to readjust the
temperature, turn the thermostat gradually until the temperature
is ideal.
The thermostat will not operate correctly if the stones are piled too
densely or they are too small. Please refer to section "Sauna heater
stones" on page 5
The thermostat has an integrated temperature limiter with a reset switch
next to the thermostat knob.