8. For installation in inaccessible false
ceilings or limited space, the connec-
tion piece (B) must be removed in-
side to connect the exhaust air hose.
To do so, first remove the connection
channel between the fan motor and
the support, then release the support
plate and push it into the hood body
(A). Then connect the exhaust air
hose and seal it. The installation is
carried out in the reverse order.
9. a) Connect up the power supply.
14
b) In extraction mode: If using an exter-
nal blower motor, connect the connect-
ing cable.
10. Insert the filter insert (E) in the hood
body (A) and screw in place. Close the
stainless steel panel.
2.
11. Carry out a function test.