Connection plan (example)
Saunasteuergerät
control unit
L1 L2 L3 N
400 V AC 3N
400 V AC 3N
Wiring diagram
9000 W
U V W
N
Model
Power rating
Invisio
9,0 kW
All cable details are minimal core dimensions in mm² of a standard copper wire cable.
Dimensions,
Model
H x W x D,
cm
Invisio
80 x 116 x 58
22
S1
U V W WB WM N
Power supply
400 V 3N AC 50 Hz
Min. size of
For sauna
air intake and
volume
exhaust vent
9 - 14 m³
35 x 5 cm
Sensor
Attention! Make sure to always
connect the neutral wire N.
Fuse protection for
control unit, A
3 x 16 A
Net weight
w/o rocks and
Rock volume
package
24,5 kg
75 kg
D
max. 9 kW
Cable main to
Cable control unit
control unit
to sauna heater
5 x 2,5²
5 x 1,5²
Power
extension
Suitable control units
required
ECON D1, D2, D3
ECON H1, H2, H3
EMOTEC DC9000
nein
EMOTEC DC9000 DLF
EMOTEC HCS9003
EMOTEC HCS9003 DLF
Emotouch II PB/AF/GF