Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting Guide - Stanley ST-125T-KFA-E Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für ST-125T-KFA-E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 12
problem
Heater fires, but Main PCB shuts
heater off after a short period of time.
Lamp is flickering, and LED display
shows "E1"
Heater will not operate, or motor runs
for short time. Lamp flickers and LED
display shows "E1"
Fan does not operate when heater is
plugged in and Power Switch is in the
"ON" position. The lamp is flickering
or on and LED Display shows "E1" or
"E2"
Lamp is flickering, and LED display
shows "E3"
Poor Combustion and / or excess soot
production
Heater does not turn on and the lamp
is not lit
© 2014, Pinnacle Products International, Inc.

TROUBLESHOOTING GUIDE

possible Cause
1. Incorrect pump pressure
2. Dirty Input, Output or Lint Filter
3. Dirty Fuel Filter
4. Nozzle is Dirty
5. Photocell lens is Dirty
6. Photocell not installed properly
7. Photocell Defective
8. Improper electrical connection
between Main PCB and Photocell
1. No paraffin in fuel tank
2. Incorrect pump pressure
3. Corroded Spark Plug or incorrect plug
gap.
4. Dirty Fuel Filter
5. Dirty Nozzle
6. Moisture in Fuel/Fuel Tank
7. Improper electrical connection
between Transformer and Circuit
Board
8. Ignitor Wire not connected to Spark
Plug
9. Defective Ignitor
1. Thermostat is set too low (Does not
apply to ST-45-KFA-E)
2. Broken electrical connection between
Main PCB and motor
1. Thermostat Switch has failed
1. Dirty Input, Output or Lint Filter
2. Dirty Fuel Filter
3. Poor quality of fuel
4. PSI is too high or too low
1. Temperature limit sensor has
overheated
2. No electrical power
3. Fuse Blown
4. Improper electrical connection
between Temperature Limit Sensor
and Circuit Board
17
Solution
1. Adjust Pump Pressure
2. Clean/replace Air Filter
3. Clean/replace Fuel Filter
4. Clean/replace Nozzle
5. Clean/replace Photocell
6. Adjust Photocell position
7. Replace Photocell
8. Check wiring connections (See Wiring
Diagrams, Page 7)
1. Fill tank with fresh paraffin
2. Adjust Pump Pressure
3. Clean/replace Spark Plug
4. Clean/replace Fuel Filter
5. Clean/replace Nozzle
6. Rinse out fuel tank with clean fresh
paraffin
7. Inspect all electrical connections. See
Wiring Diagrams
8. Re-attach Ignitor wire to Spark Plug
9. Replace Ignitor
1. Rotate thermostat to a higher setting
2. Inspect all electrical connections. See
Wiring Diagrams (Page 7)
1. Replace Thermostat Switch
1. Clean/replace Air Filter
2. Clean/replace Fuel Filter
3. Be sure fuel is not contaminated or old
4. Use proper pressure
1. Push Power Switch to "OFF" and allow
heater to cool for 10 minutes. Push
Power Switch to back to "ON"
2. Check power cord and extension cord
to insure of proper connection. Test
power supply
3. Check/replace Fuse
4. Inspect all electrical connections.
Wiring Diagrams (Page 7)

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis