TRIMMER
T.R.A.
not used;
T.C.A.
Automatic Closing time adjustment: from about 1 to 120 seconds (see dip-switch
no. 1);
FR.
obstacle detection sensitivity adjustment.
Note: by rotating the TRIMMER FR. clockwise the sensitivity of the gearmotor
to obstacles diminishes and therefore the thrust force increases; vice-versa, by
rotating it counter-clockwise, the sensitivity of the gearmotor to obstacles
increases and therefore the thrust force diminishes.
Dip switch
AUTOMATIC
1
CLOSING
2
2 / 4 STROKE
CLOSES AGAIN
3
AFTER THE
PHOTOCELL
4
NO REVERSE
PRE-
5
FLASHING
6
FOTOTEST
MASTER/
7
SLAVE
BAR
8
LED
9-10-11
Selection of barrier model and bar lenght
Dip 9
Dip 10
Off
Off
On
Off
Off
On
On
On
Off
Off
On
Off
Off
On
On
On
IMPORTANT: In case the boom length change, a new setting of the dips # 9, 10 and 11
will be required. Before the new setup, however, it is necessary to proceed to a HARD
RESET (see page 24) of the controller.
when completely open, closure is automatic after the set time on the
On
T.C.A. trimmer has past.
Off
the closing manoeuvre requires a manual command.
when the automation is operating, a sequence of opening/closing com-
On
mands causes the bar to OPEN-CLOSE-OPEN-CLOSE, etc.
in the same conditions, the same sequence of commands causes the
Off
bar to OPEN-STOP-CLOSE-STOP-OPEN-STOP, etc . (step-by step
function) (see also dip switch
after the photocell is activated (input 7 - 9), the automation closes
On
automatically after 5 seconds.
Off
function off.
On
the bar ignores the closure command during opening.
Off
the bar responds as established by dip switch No. 2.
On
the pre-flashing function is enabled.
Off
the pre-flashing function is disabled.
On
the "photocell test" function is enabled.
the "photocell test" function is disabled.
Off
Note: to be used when the photocells are not used.
enables the MASTER mode in the master/slave configuration (see T-
On
COMM instructions).
enables the SLAVE mode in the master/slave configuration (see T-
Off
COMM instructions), or standard operation (single motor).
On
when the boom is lifted all LEDs remain OFF.
when the boom is lifted all LEDs behave as per setting of wire terminals
Off
16-18 (default: FLASHING).
Dip 11 Model
Off
RBLO / RBLO-X bar ≥ 2 m ≤ 2,5 m
Off
RBLO / RBLO-X bar > 2,5 m ≤ 3,5 m
Off
RBLO bar > 3,5 m ≤ 4 m
Off
RBLO-X bar > 3,5 m ≤ 4 m
On
LUXE bar ≥ 4 m ≤ 4,5 m (including accessories)
On
LUXE bar > 4,5 m ≤ 5,5 m (including accessories)
On
LUXE bar > 5,5 m ≤ 6,5 m (including accessories)
On
LUXE bar > 6,5 m (including accessories)
K206MA
4).