7.3.6. A ddress on the internal RIO bus:
DIP switches 1 to 3
Each peripheral terminal has a unique address. This address is set
on the valve terminal via DIP switches 1 to 3.
DIP 1
DIP 2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
18
DIP 3
Address
Peripheral
terminal
OFF
0
OFF
1
OFF
2
OFF
3
ON
4
ON
5
ON
6
ON
7
english
7.3.7. Mode inputs: DIP switches 4 and 5
NOTE!
The input modes allow the entries (feedback indicator) to be
assigned in different ways in the process image of the inputs
(PAE).
0
No entries available
1
Normal mode
2
3
Mode: shifted inputs
4
Mode: halved inputs
5
6
CAUTION!
7
If there are no inputs available, both switches must be set to OFF.
Type 8640
Installation
DIP 4
OFF
ON
OFF
ON
DIP 5
OFF
OFF
ON
ON