Assembly
1. Install the base on the column .
Install one prepared base on each column .
1. Insert the column between the side plates of the base .
2. Fasten in place with two prepared M8 bolts (60 mm) and
nuts .
• The bolt should be securely tightened to the torque given
below.
12~14 N•m
2. Install plates on the column .
Install prepared plates on each column .
1. Fasten prepared plates to the column with prepared M8
bolts (60 mm) and nuts .
Two plates should be installed.
• The bolt should be securely tightened to the torque given
below.
12~14 N•m
3. Assemble the frame and the stay .
1. Insert the frame into the stay , and fasten in place with
one prepared M16 bolt .
2. Fasten one plate set to the stay with three prepared M8
bolts (60 mm) and nuts .
One plate set should be installed.
• The bolt should be securely tightened to the torque given
below.
M16 bolt 25~35 N•m
M8 bolt 12~14 N•m
4. Install onto the Plasma Display.
Install each column assembled in the above step 2 onto the
display.
(Note)
Each column should be installed so that the L/R label
affixed to it faces outside.
1. Prepare six sets of one M16 bolt , one spring washer and
one plain washer , which should be assembled in the order
shown in the right figure.
2. Place each column on the display, and temporarily fix it with
prepared bolts from the top down.
3. Confirm that the each column has been properly seated on the
display, and then tighten the bolts securely.
• The bolt should be securely tightened to the torque given
below.
25~35 N•m
(Inclined hanging)
1
2
Prepared M8 bolt
(60 mm)
Install the base on column with
the surface of the column to which
the gaskets have been attached
facing down.
Prepared plates
Prepared M8 bolt
(60 mm)
Prepared M8 bolt
Prepared
(60 mm)
M16 bolt
1
2
1
2
3
Plasma Display
Column
19