CONTROL PANEL FOR ONE 18/24V MOTOR WITH ENCODER
•
ABSORPTION CHECK FUNCTION
•
STATUS OF INPUTS SIGNALLED BY LEDs
•
INCORPORATED FLASHING CIRCUIT
•
ENCODER SENSOR FOR SELF-LEARNING OF TRAVEL
•
433.92 MHz 2 CHANNEL BUILT-IN RADIO RECEIVER (CH)
•
BATTERY CHARGER BOARD (INTEGRATED)
•
DIAGNOSTICS OF MALFUNCTIONS SIGNALLED BY LED
•
POSSIBILITY OF ENERGY SAVING OPERATION
ATTENTION:
-
do not use single cables (with one single wire), ex. telephone cables, in order to avoid
breakdowns of the line and false contacts;
-
do not re-use old pre-existing cables;
-
we recommend to use the TAU cable code M-03000010C0 to connect the motors to the
control board.
INTRODUCTION
The K126MA board has two working modes, selectable through the J6 jumper (see wiring diagram).
J6 Jumped:
J6 Not jumped:
Once the connection is achieved, in low-energy mode, press the PROG button briefly:
•
All the green LEDs must be on (each of them corresponds to a Normally Closed input). The go off
only when the controls to which they are associated are operated.
•
All the red LEDs must be off (each of them corresponds to a Normally Open input). The light up
only when the controls to which they are associated are operated.
TECHNICAL CHARACTERISTICS
Board power supply
Max motor power DC
Fast acting fuse for protection of input power supply 13,5V AC (F4 - 5x20)
Fast acting fuse for battery charger protection (F5 - 5x20)
Fast acting fuse for protection of auxiliary circuits 18V
Motor power supply circuits voltage
Auxiliary device circuits supply voltage
Logic circuits supply voltages
Operating temperature
18V for
MASTER-R and T-ONE8BR
1
24V for MASTER-R and T-ONE8BR
2
CONNECTIONS TO TERMINAL BOARD
Terminals
Function
FS1 - FS2
POWER SUPPLY
1 - 2
AUX INPUT
18
standard mode, i.e. the control unit is powered all the time;
low consumption mode, at the end of each maneuver the board automatically switches
OFF itself and all the auxiliary devices connected. The board will automatically switch
ON again activating the OP/CL contact or pressing the remote (mode where power is
supplied by other energy sources, ex. batteries charged by a photovoltaic panel).
Description
13,5V (18V for
er supply input – Fed by
by the fuses on the 230V AC power supply.
external power input (ex. Photovoltaic system 12V DC).
Note: if this input is used, jump J7 appropriately (see wiring
diagram).
ATTENTION: POWERING THE CONTROL UNIT WITH AN EX-
TERNAL SOURCE, ALL THE OTHER 18V (24V for MASTER-
R) DC OUTPUTS BECOME THE SAME AS THE OUTSIDE
VOLTAGE.
DC (F3 - 5x20)
2
MASTER-R and T-ONE8BR) AC control unit pow-
the toroidal transformer and protected
K126MA
13,5V
AC - 50 Hz
1
300VA - 18V
DC
2
F 16A
F 10A
F 2A
18V
DC
2
18V
DC
2
5V DC
-20 °C ÷ +55 °C