3) Installation
!
The installation must be carried out by qualified personnel in compliance with current legislation, standards and reg-
ulations, and the directions provided in this manual.
3.1) Preliminary checks
Before proceeding with the installation:
• Check that all the materials are in excellent condition, suitable for
use and compliant with current standards.
• Ensure that the structure of the gate is suitable for automation.
• Ensure that the mounting positions of the various devices are pro-
tected from impact and that the mounting surfaces are sufficiently
sturdy.
• Install cable or pipe leads only at the bottom of the unit; for no rea-
son whatsoever must the side and top walls be perforated. The
cables must only enter the unit from the bottom!
• Insert suitable mechanical stops, anchored to the ground, both for
opening and closing manoeuvres.
• Components must never be immersed in water or other liquids.
Keep away from heat sources and open flames; in acid, saline or
potentially explosive atmosphere; this could damage A60 and
cause malfunctions or hazardous situations.
• If there is an access door in the leaf, or within the range of move-
ment of the gate, make sure that it does not obstruct normal trav-
el. Mount a suitable interlock system if necessary.
• Only connect the control unit to a power supply line equipped with
a safety grounding system.
3.2) Fixing the control unit
Insert the two screws in the upper holes provided, sliding them on the guide as in fig. 3a and partly screwing them in. Turn the control unit
through 180° and perform the same operation with the other 2 screws. Fix the control unit on to the wall.
Fix the cover on the desiderd part (with opening on the right or left), press firmly on the arrows.
To remove the cover, press with a screwdriver on the join and push upwards at the same time.
3a
6
3b
• The power supply line must be protected by suitable magne-
tothermal and differential switches.
• A disconnection device must be inserted in the power supply line
from the electrical mains (the distance between the contacts must
be at least 3.5mm with an overvoltage category of III) or equivalent
system, for example an outlet and relative plug. If the disconnec-
tion device for the power supply is not mounted near the automa-
tion, it must have a locking system to prevent unintentional, unau-
thorised connection.
3c
3d