Thank you for buying this product, our company is sure that you will be more
than satisfied with the product's performance. The product is supplied with
a "Warnings" leaflet and an "Instruction booklet". These should both be
read carefully as they provide important information about safety, installa-
tion, operation and maintenance. This product complies with the recognised
technical standards and safety regulations. We declare that this product is
in conformity with the following European Directives: 2004/108/EEC and
2006/95/EEC, 98/37/EEC (and subsequent amendments).

1) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product can
cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences result-
ing from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the fol-
lowing European Directives: 2004/108/CEE, 2006/95/EEC, 98/37/EEC
and subsequent amendments. As for all non-EEC countries, the above-
mentioned standards as well as the current national standards should
be respected in order to achieve a good safety level.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing clos-
ing structures (door, gates etc.), as well as from any deformation which
might occur during use.
The installation must comply with the provisions set out by the following
European Directives: 2004/108/CEE, 2006/95/EEC, 98/37/EEC and
subsequent amendments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing.
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers' components are
used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation opera-
tion area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the automa-
tion system, and always request the assistance of qualified personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.
Check that the range of temperature indicated is compatible with the
place of installation.
During installation, the power supply wires must be laid at an adequate
distance from the motor, in order to prevent them from being affected by
excessive temperature.
Power supply mains wires (230V) must be clearly separated from wires
having very low safety voltage (SELV 24V), otherwise they must be
provided with additional insulation, at least 1mm thick.
INSTALLATION MANUAL
The cables entering the control unit must be kept away from heated parts
(dissipator, braking resistor etc.).

2) GENERAL OUTLINE

The LEO-D-MA control panel is supplied by the manufacturer with standard
setting. Any alteration must be set by means of the incorporated display
programmer or by means of universal palmtop programmer. The Control
unit completely supports the EELINK protocol.
It is available in two versions: one for external installation, inside the SD box,
the other fitted and pre-wired inside the controller.
Its main characteristics are:
-
Slow down of end-of-run speed.
-
Electronic torque setting
-
Adjustable electrodynamic braking
-
Closing / opening limit-switch inputs
-
Separate inputs for safety devices
-
Clock input
-
Serial protocol connection input (optional)
-
Incorporated radio receiver
The board is provided with a terminal board which can be pulled out for
easier maintenance or replacement. The board is supplied with a series of
pre-wired jumpers to facilitate the installer's work.
The jumpers relate to the following terminals: 21-23, 21-24 and 21-30. If the
above-mentioned terminals are in use, remove their respective jumpers.
CHECK
The control unit runs a check on the operating relays and safety mecha-
nisms (photocells, sensor ridge, etc.) before performing opening and closing
cycles.
CONNECTION OF PHOTOCELLS AND SENSOR RIDGE:
By convention, refer to a receiver (Rx- fig.7) with 5 terminals of which termi-
nals 1 and 2 are for the 24V~ power supply, terminal 3 is shared, terminal 4
is the normally closed contact when at rest, terminal 5 is the normally open
contact when at rest. The contact is not powered.
LEGEND
RX: photocell or infrared edge receiver.
TX: photocell or infrared edge transmitter.
Numerous combinations can be obtained between photocells and infrared
edges; the most frequently used types of connections are illustrated in
figures 7 to 14.
-
Fig.7 shows the connection of LEO-D-MA with 1 photocell and 1 infrared
edge unchecked. In the logic menu, set the "test phot" and "test bar"
functions to OFF.
-
Fig.8 shows the connection of LEO-D-MA with 1 photocell and 1 infrared
edge checked.
8a
8b
8a+8b
In the logic menu, set the "test phot" and "test bar" functions to ON.
-
Fig.9 shows the connection of LEO-D-MA with 2 photocells and 2 infrared
edges checked.
9a
9b
9a+9b
In the logic menu, set the "test phot" and "test bar" functions to ON.
-
Fig.10 shows the connection of LEO-D-MA with 3 photocells and 3 infrared
edges checked.
10a
10b
10a+10b : 3 photocells + 3 edges checked
In the logic menu, set the "test phot" and "test bar" functions to ON.
-
Fig.11 shows the connection of LEO-D-MA with 4 photocells and 1 infrared
edge checked.
11a
11a+11b : 4 photocells + 1 edge checked
In the logic menu, set the "test phot" and "test bar" functions to ON.
-
Fig.12 shows the connection of LEO-D-MA with 1 photocell and 4 infrared
edges checked.
11b
11a+11b : 1 photocell + 4 edges checked
In the logic menu, set the "test phot" and "test bar" functions to ON.
-
Fig.13 shows the connection of LEO-D-MA with 4 photocells and 2 infrared
edges checked.
In the logic menu, set the "test phot" and "test bar" functions to ON.
-
Fig.14 shows the connection of LEO-D-MA with 2 photocells and 4 infrared
edges checked.
In the logic menu, set the "test phot" and "test bar" functions to ON.
: 1 photocell checked
: 1 infrared edge checked
: 1 photocell + 1 edge checked
: 2 photocells checked
: 2 infrared edges checked
: 2 photocells + 2 edges checked
: 3 photocells checked
: 3 infrared edges checked
: 4 photocells checked
: 4 infrared edges checked