Introduction

The purpose of this user manual is to inform users how their air source heat
to change settings on the main controller.

Overview of the System

The Mitsubishi Electric Air to Water (ATW) heat pump system consists of the fol-
lowing components; outdoor heat pump unit and indoor cylinder unit or hydrobox
incorporating main controller.

How the Heat Pump Works

Space heating and DHW
Heat pumps take electric energy and low grade heat energy from the outdoor air
to heat refrigerant which in turn heats water for domestic use and space heating.
this is the ratio of heat delivered to power consumed.
The operation of a heat pump is similar to a refrigerator in reverse. This process
is known as the vapour-compression cycle and the following is a more detailed
explanation.
Low temperature renewable heat
energy taken from the environment
2 kW
Electrical power input
1 kW
3
Useful energy output
3 kW
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction con-
cerning the use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the appli-
ance.
This user manual should be kept with the unit or in an accessible place for
future reference.
Schematic of package cylinder system
(Plate heat exchanger)
3. Expansion valve
(Outdoor unit air heat exchanger)
1. The refrigerant within the circuit is compressed as it passes through the com-
pressor. It becomes a hot highly pressurised gas. The temperature also rises
typically to 60°C.
2. The hot refrigerant gas is then condensed as it passes across one side of a
plate heat exchanger. Heat from the refrigerant gas is transferred to the cooler
side (water side) of the heat exchanger. As the temperature of the refrigerant
decreases its state changes from a gas to a liquid.
3. Now as a cold liquid it still has a high pressure. To reduce the pressure the liq-
uid passes through an expansion valve. The pressure drops but the refrigerant
remains a cold liquid.
and evaporates. It is at this point when some of the free heat energy in the out-
side air is absorbed by the refrigerant.
It is only the refrigerant that passes through this cycle; the water is heated as it
travels through the plate heat exchanger. The heat energy from the refrigerant
passes through the plate heat exchanger to the cooler water which increases in
temperature. This heated water enters the primary circuit and is circulated and
used to serve the space heating system and indirectly heat the contents of the
DHW cylinder (if present).
2. Condenser
1. Compressor
4. Evaporator