6
www.aeg.com
5. CONTROLS
The hood is fitted with a control panel with
aspiration speed selection control and a
light switch to control cooking area lights.
Use the high suction speed in cases
of concentrated kitchen vapours. It is
recommended that the cooker hood suction
is switched on for 5 minutes prior to cooking
and to leave in operation during cooking
and for another 15 minutes approximately
after terminating cooking.
The control switches are located on the
unit's front panel.
T1
Button Speed (power) of suction 1
T2
Button Speed (power) of suction 2
T3
Button Speed (power) of suction 3
T4
Button ON/OFF Speed (power) of
suction 4
Note: The Speed (power) of suction 4
remains in function for 5 minutes, then
the it returns to the previous setting.
T5
Button for filter saturation control
T6
Button OFF speed
Button for control panel activation-
deactivation
T7
Button ON/OFF lights
Button for activation/deactivation of
charcoal filter saturation control
Delayed switch-off function for the
suction speed (power):
Select the desired speed and press the
same button again for more than 2 sec.;
the button flashes to indicate that the
function has been activated. Press again to
deactivate the function.
The selected speed will turn off after:
Speed (power) of suction 1: 20 minutes
Speed (power) of suction 2: 15 minutes
Speed (power) of suction 3: 10 minutes
Speed (power) of suction 4: 5 minutes
T7
T6
T1
Note: a remote control can be purchased
apart, contact the local authorized dealer.
Note: The hood is equipped with a
protection system against disturbances of
the mains power network; in case of peaks
exceeding 2kVolts, the hood will reactivate
autonomously after approximately two
minutes from the last disturbance.
T2
T3
Function Activation – Deactivation
control panel
Press the
T6
button for more than 5
seconds
Function Activation – Deactivation
control of charcoal filter saturation
With the hood off press the
more than 5 seconds.
Button
T5
flashes:
Twice to indicate that the saturation control
for the charcoal filter has been activated
Once to indicate that the saturation control
for the charcoal filter has been deactivated
Function of filter saturation control and
reset
At regular intervals, depending on how
long the hood is used, the button
to indicate that it is necessary to carry out
the maintenance of the filters according to
instructions in the related paragraphs.
Button
T5
lights up with steady light: it is
necessary to perform maintenance on the
grease filter
Button
T5
lights up flashing: it is necessary
to perform maintenance on the charcoal
filter.
Reset filter saturation indicator:
With the hood off press the
more than 2 sec.
Repet the operation if necessary.
T4
T5
T7
button for
T5
lights
T5
button for