Error Messages

When you turn on the fixture, it will make a reset first. The display may show an error message while
there are problems with one or more channels. The error message stands for the channels equipped
with a testing sensor.
For example, when the display shows "Color Wheel", it means there is some error in the color wheel
channel. If there are some errors on several channels at the same time, you may see the error
messages flash repeatly for 5 times, and then the fixture will generate a reset signal, all the stepper
motors will reset. If the error messages maintain after performing reset more than 3 times, it will
detect whether the fixture has more than 3 errors. If the fixture has more than 3 errors (including 3
errors), all the channels can not work properly; but if the fixture has less than 3 errors, only the
channels which have errors can not work properly, others can work as usual.
The respective error message will appear after the reset of the fixture if the channels magnetic-indexing
circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on
the main PCB). The channel feature is not located in the default position after the reset.
The different error messages are:
PAN Moving
TILT Moving
COLOR Wheel
Cyan COLOR
Magenta COLOR

CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material
abrading or damages) and must not rotate with unbalances.
4) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The lens has to be replaced when it is obviously damaged,
so that its function is impaired, e. g. due to cracks or deep scratches!
The fresnell lens will require weekly cleaning as smoke-fluid tends to building up residues, reducing the light-
output very quickly. The cooling-fans should be cleaned monthly.
Yellow COLOR
Effect wheel
Stepless zoom
Strobe
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!