Technical data

General data and operating conditions

2
Technical data
General data and operating conditions
Standards
Conformity
Approval
Protection
Enclosure
Enclosure
Insulation resistance
Environmental conditions
Climate
Storage
Transport
Operation
Site altitude
Pollution
Vibration resistance
26
CE
Low-Voltage Directive (73/23/EEC)
UL 508C
Power Conversion Equipment (file no. 132659)
EN 60529
IP 20
NEMA 250
Protection against accidental contact acc. to type 1
EN 61800-5-1
Overvoltage category III
Reduction from 2000 m: Overvoltage category II
IEC/EN 60721-3-1
1K3 (-25 ... +60 °C)
IEC/EN 60721-3-2
2K3 (-25 ... +70 °C)
IEC/EN 60721-3-3
3K3 (-10 ... +55 °C)
Power derating at +45 ... +55 °C: 2.5 %/°C
0 ... 4000 m amsl
Power derating at 1000 ... 4000 m amsl: 5 %/1000 m
EN 61800-5-1
Pollution degree 2
Germanischer
General conditions: acceleration resistant up to 0.7 g
Lloyd