DESCRIPTION:
1. 230V Mains input with male IEC cable connector
2. 230V Mains output with female IEC cable connector
3. DMX input with male XLR cable connector
4. DMX input with female XLR cable connector
5. CA-8 controller input
6. Internal microphone
7. "Auto DMX-address" button
8. 4 fixing holes
9. Plastic screws used to fix the front cover on the base
JB SYSTEMS
®
OPERATION MANUAL
3/40
LED PANEL
ENGLISH
ELECTRICAL INSTALLATION + ADDRESSING
Important: The electrical installation should be carried out by qualified personal only,
according to the regulations for electrical and mechanical safety in your country.
Electrical installation for 1 standalone unit:
 Just insert the mains cable. The unit starts working immediately in stand-alone mode
Remark: You can connect a CA-8 remote controller to the unit if you want to have more control. Refer to
section "C" of the operating instructions to learn how to do this.
Electrical installation for two or more units in master/slave:
 Connect 2 to maximum 16 units together using good quality
balanced microphone cables (like for example JB Systems ref. 7-
0063). The unit that has no cable connected to its DMX-input will
react as "master", the others are the slave units.
 Make sure that all units are connected to the mains.
 Done!
Remark: You can connect a CA-8 remote controller to the master
unit if you want to have more control over the master/slave operation.
You can also connect the LEDCON 01 remote controller, in this case
all units will respond equally (all units have the same color)
Electrical installation for two or more units in DMX-mode:
 The DMX-protocol is a widely used high speed signal to control intelligent light equipment. You need to
"daisy chain" your DMX controller and all the connected units with a good quality balanced cable (ex. JB
Systems ref. 7-0063).
 To prevent strange behavior of the light effects, due to interferences, you must use
a 90Ω to 120Ω terminator at the end of the chain. Never use Y-splitter cables, this
simply won't work!
 Make sure that all units are connected to the mains.
 Each LED panel in the chain needs to have its proper starting address so it knows which commands
from the controller it has to decode. In the next section you will learn how to set the DMX addresses.