2. Procedure rule
Wood gasification boilers work in pirolitic wood distillation process. When the air is limited
wood changes into charcoal while burning up. In the same time wood gas appears, which next
relocates to burner's nozzle and there it is burnt at the bottom of the boiler. Such method of wood
burning allows for its effective using as fuel. Orlan boilers are made for burning wood billets (use
minced wood only as an addition - it should be mixed with bigger wood parts as not to allow for
burner's nozzle littering) .
3. Installation
Wood boilers are to be installed according to the present norms and rules. The requirements
of norm PN 87/B 02411 according building of solid fuel boiler room and the norm PN 91/B 02413
according open system boilers' producing should be taken into account. These norms and
rules should be followed, however, caution is required as national rules in countries in which the
product is sold may replace above-mentioned norms.
In case of boiler assembly outside the Poland, rules and norms should be followed according
to solid fuel boiler assembly in countries in which the product is sold. Eko-Vimar Orlanski wood
gasification boilers type SUPER are adjusted for installation in closed systems.
Eko-Vimar Orlański company prescribes using chimney inputs which preserve against the
chimney permeating. The company doesn't take responsibility in case of faults resulting from not
using chimney inputs .
1. Chimney flue should correspond to the parameters of „DIAGRAM OF CHIMNEY CHOOSING
ACCORDING TO THE DIN 4705 NORM".
2. Boiler room should be large enough to enable boiler's cleaning (>2,2 m).
3. The distance between the boiler and the partitions should enable right access for all of the
boiler's parts - it shouldn't be less than - look at "Orlan boiler placing".
4. There shouldn't be any cables nor electric installations which aren't for boiler room using.
26
Pic.1 Orlan boiler placing.