Motor protection tripped, e.g. by
insufficient cooling (cooling fins cov-
ered).
− Switch compressor OFF at the
On/Off switch; remove cause for
overheating; let cool off for
approx. 10 minutes; reset the
motor protection switch; switch
compressor ON again at the On/
Off switch.
Compressor runs but does not build
up sufficient pressure.
Condensate drain of pressure ves-
sel leaky.
− Check gasket of drain cock(s);
replace if necessary.
− Tighten drain cock(s) fingertight.
Check valve leaky.

10. Technical specifications

Suction capacity
Free air delivery (volume flow rate)
Filling rate
Working pressure (compression end pressure)
Pressure vessel volume
No. of air outlets
Compressor pump model
No. of cylinders
Speed (compressor pump)
Motor capacity
Supply voltage (50 Hz)
Rated current
Fuse protection min.
Degree of protection
Maximum overall length when using extension cables with:
2
– 3 x 1.5 mm
lead cross-section
2
– 3 x 2.5 mm
lead cross-section
Oil grade
Oil qantity for oil change
Dimensions: length x width x height
Weight
Sound pressure level L
PA
Sound power level L
WA
− Have check valve serviced by
qualified service centre.
Air tool is not supplied with sufficient
pressure.
Pressure regulator not opened wide
enough.
− Open pressure regulator more.
Hose connection between compres-
sor and air tool leaky.
− Check air hoses, replace defec-
tive parts if necessary.

8. Repairs

A
Danger!
Repairs to power tools must be
carried out by qualified electricians
only!
at 4 m maximum
Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.
Please attach a description of the fault to
the power tool.

9. Environmental protection

The machine's packaging can be 100 %
recycled.
Worn out devices and accessories con-
tain considerable amounts of valuable
raw and plastic materials, which can be
recycled.
These instructions are printed on chlo-
rine-free bleached paper.
l/min
l/min
l/min
bar
l
-1
min
kW
V
A
A
m
m
l
cm
kg
dB (A)
dB (A)
ENGLISH
290
165
195
10
50
2
B 2800
2
1300
2.0
400
3.7
10 (time-lag)
IP 44
100
160
10 W 40
0.21
88 x 49 x 77
46
71 ± 3
91 ± 3
15