When installing many flush-mount actuators in
installation boxes that are one above the other or
adjacent to one another (connected or not), the total
switching current of 16 A is not to be exceeded!
The installation of the described actuators is shown
in the following connection diagrams.
Connect the actuators to L and N for the supply.
Channels for buttons exist at the button inputs.
Run the channel circuit to the consumer.
No operational elements are actually located on the
devices. For teaching directly without HomeMatic
Centre, you must (even if only temporarily) connect
buttons!
The control inputs are connected to mains
power. Use only mains power capable
buttons and wiring! Only connect buttons to the
inputs, no switches! These would cause faulty
functionality of the device (teach mode)!
35