Environmental conditions
Vibration, DIN EN 60068-2-6: 1996 .................................... ≤ 100 m/s², sine 50-2000 Hz
Shock, DIN EN 60068-2-27: 1995 ........................................ ≤ 1000 m/s², half-sine 11 ms
EMC ........................................................................... - Transient emissions, DIN EN 61000-6-3: 2007
to disturbance, DIN EN 61000-6-2: 2006
Working temperature ............................................................ 0 °C...+70 °C, optional -20 °C...+70 °C
Storage temperature .............................................................. -30 °C...+85 °C, dry
Relative humidity, DIN EN 60068-3-4: 2002 ........................ 98 %, non condensing
Protection class, DIN EN 60529: 1991 ................................. ≤ IP 65, dependent on the type of connector / connection technology
Stray magnetic field, measured on the measuring level ........ < 3 mT
Pressure resistance, optional ................................................ 600 bar static
Mechanical characteristics
Measuring principle .............................................................. magnetostrictive
1)
Measuring length, standard ............................................... 50 mm...2000 mm > 2000 mm on request, in steps of 50 mm
Measuring length in mm ........................................................ 150, 300, 500, 700, 750, 1000, 1500, 2000, 2500, 3000,
Resolution .............................................................................. ≤ 0.05 mm (Analog)
Resolution .............................................................................. is defined in external evaluation electronics (Start-Stop)
1)
Resolution .......................................................................... ≤ 0.005 mm
Resolution .............................................................................. ≤ 0.01 mm
1)
Linearity deviation, related to the measuring length ......... ± 0.1 mm up to 1.000 mm / ± 0.15 mm > 1.000 mm
Linearity deviation, related to the measuring length ............ < 0,05 %
1)
Reproducibility ................................................................... ≤ 0.005 mm
Reproducibility ...................................................................... ≤ 0.01 mm
1)
Hysteresis ........................................................................... ≤ 0.02 mm up to 1.500 mm / ≤ 0.1 mm > 1.500 mm
Hysteresis .............................................................................. ≤ 0.1 mm
Temperature coefficient, related to the measuring length ..... < 40 ppm/°C (Analog, FIPIO)
Temperature coefficient, related to the measuring length ..... < 8 µm/°C ≤ 500 mm / < 15 ppm/°C > 500 mm
Straight line velocity.............................................................. ≤ 1 m/s at a resolution of 0.01 mm (ISI)
Straight line velocity and mounting position ......................... no restrictions
Material - measuring rod ...................................................... Cr/Ni - alloy
Rod end mounting ................................................................. Option
1)
EtherCAT, Powerlink, PROFINET
Printed in the Federal Republic of Germany
08/05/2011
> 3000 on request
TR - ELA - BA - DGB - 0004 - 03
Technische Daten [Technical data]
- Immunity
TR-Electronic GmbH 2007, All Rights Reserved