3.4.6

Manual adjustment of set values

The set values for voltage, current and power are the fundamental operating possibilities of a power supply and hence
the two rotary knobs on the front of the device are always assigned to two of the the values in manual operation.
As a fourth value there is the internal resistance, for which the resistance mode (R mode) has to be activated in
the MENU first. Refer to „3.4.3. Configuration via MENU" and „3.2.4. Internal resistance regulation" for details.
Set values can be entered manually in two ways: via rotary knob or direct input.
Entering a value changes it at any time, no matter if the output is switched on or off.
When adjusting set values, upper or lower limits may come into effect. See section „3.4.4. Ad-
justment limits". Once a limit is reached, the display will show a note like "Limit: U-max" etc. for
1.5 seconds next to the adjusted value.
► How to adjust set values U, I, P or R with the rotary knobs
1.
First check whether the value to be changed is assigned to one of the rotary knobs.
The main screen displays the assignment as depicted in the figure to the right.
2.
If, as shown in the example, the assignment is voltage (U, left) and power (P, right),
and it is required to set the current, then the assignments can be changed by tap-
ping this touch area. A set of selection fields then appears.
3.
After successful selection, the desired value can be set within the defined limits. Selecting a digit is done by
pushing the rotary knob which shifts the cursor clockwise (digit will be underlined):
►How to adjust values via direct input:
1.
In the main screen, depending on the rotary knob assignment, values
can be set for voltage (U), current (I), power (P) or resistance (R) via
direct input by tapping on the set/actual value display areas, e.g in the
uppermost area of voltage.
2.
Enter the required value using the ten-key pad. Similar to a pocket
calculator the key
Decimal values are set by tapping the point key. For example, 54.3 V
is set with
3.
The display reverts to the main page and the set values take effect.
EA Elektro-Automatik GmbH
Page 48
Helmholtzstr. 31-33 • 41747 Viersen
Germany
clears the input.