Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Replacing The Power Cable; Cleaning, Maintenance And Ordering Of Spare Parts - EINHELL RT-RH 32 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für RT-RH 32:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
stop (7).
Set the depth stop (7) to the same level as
the drill bit.
Pull the depth stop (7) back by the required
drilling depth.
Retighten the locking screw (a).
Now drill the hole until the depth stop (7) tou-
ches the workpiece.
5.3. Tool insertion (Fig. 4)
Clean the tool before insertion and apply a
thin coating of drill bit grease to the shaft of
the tool.
Pull back and hold the locking sleeve (2).
Insert the dust-free tool into the tool mounting
as far as it will go whilst turning it. The tool will
lock itself.
Check that it is properly secure by pulling the
tool.
5.4 Tool removal (Fig. 5)
Pull back and hold the locking sleeve (2) and re-
move the tool.
5.5 Dust collection device (Fig. 6)
Slide the dust collection device (a) over the drill
bit before carrying out any hammer drilling verti-
cally above your head.

6. Operation

Danger
To prevent all danger, the machine must only be
held using the two handles (6/8). Otherwise there
may be a risk of suff ering an electric shock if you
drill into cables.
6.1 Switching on and off (Fig. 1)
To switch on:
Press the control switch (4).
To switch off :
Release the control switch (4).
6.2 Hammer stop facility (Fig. 7)
The hammer drill has a hammer stop facility for
gentle initial drilling.
Turn the rotary switch for the hammer stop
facility (5) to position (B) to switch off the
hammer facility.
To switch on the hammer facility again the
rotary switch for the hammer stop facility (5)
must be turned back to position (A).
GB
6.3 Rotation stop facility (Fig. 8 / 9)
The rotation function of the hammer drill can be
switched off for chiseling jobs.
To do this, press the button (C) on the rotary
switch (3) whilst at the same time turning the
rotary switch (3) into position A (see Fig. 8).
To switch on the rotation facility again, press
button (C) on the rotary switch (3) whilst at
the same time turning the rotary switch (3)
into position B (see Fig. 9).
Notice
Please note that it is not possible to operate the
hammer drill with the hammer stop and rotation
stop facilities both active at the same time.
Notice
Only low pressure is required for hammer drilling.
Excessive pressure will exert an unnecessary
force on the motor. Check the drill bits at regular
intervals. Sharpen or replace blunt drill bits.

7. Replacing the power cable

Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
Danger!
Always pull out the mains power plug before star-
ting any cleaning work.
8.1 Cleaning
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low
pressure.
We recommend that you clean the device
immediately each time you have finished
using it.
Clean the equipment regularly with a moist
cloth and some soft soap. Do not use
cleaning agents or solvents; these could at-
tack the plastic parts of the equipment. Ensu-
re that no water can seep into the device. The
ingress of water into an electric tool increases
- 16 -

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis