linesensor {line_num} label set "{name}"
linesensor {line_num} label show
linesensor {line_num} events set {OFF=0|ON=1} enables events on/off
linesensor {line_num} events show
linesensor {line_num} events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2,E
VT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER=5}"
linesensor {line_num} events type show
linesensor {line_num} phonebook sms events set
"{1..20}"
linesensor {line_num} phonebook sms events
show
linesensor {line_num} maxval set {float}
linesensor {line_num} maxval show
linesensor {line_num} minval set {float}
linesensor {line_num} minval show
linesensor {line_num} hyst set {float}
linesensor {line_num} hyst show
linesensor {line_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3} port
set {port_num}
linesensor {line_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3} port
show
linesensor {line_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3}
state set {OFF=0|ON=1|DISABLED=2}
linesensor {line_num} {BELOWMIN=0|
ABOVEMIN=1|ABOVEMAX=2|BELOWMAX=3}
state show
modbus
modbus enabled set <off=0/on=1>
modbus enabled show
modbus port set <ip_port>
modbus port show
port
port {port_num} state set {OFF=0|ON=1}
port {port_num} state show
port all state set "{port_list}" {OFF=0|ON=1}
port all state {view _mode} show
port {port_num} reset
port {port_num} toggle
port {port_num} batch set {OFF=0|ON=1} w ait
{num_secs} {OFF=0|ON=1}
port {port_num} batch cancel
port {port_num} label set "{name}"
port {port_num} label show
port {port_num} initstate coldstart set {OFF=0|
ON=1|REMEMBER=2}
port {port_num} initstate coldstart show
port {port_num} initstate delay set {num}
port {port_num} initstate delay show
port {port_num} gsm pin set "{pin_num}"
port {port_num} gsm pin show
port {port_num} repow erdelay set {num}
port {port_num} repow erdelay show
port {port_num} resettime set {num}
port {port_num} resettime show
port {port_num} w atchdog enabled set {OFF=0|
ON=1}
port {port_num} w atchdog enabled show
port {port_num} w atchdog mode set {OFF=0|
PORT_RESET=1|IP_MS=2|IP_MS_INV=3}
Expert Power Control 1202/1292
sets line meter to label
show s label of line meter
show s if events are enabled
enables different event types
show s w hat event types are enabled
sets for w hat phonebook entries SMS are sent
show s for w hat phonebook entries SMS are sent
sets maximum value for line meter
show s maximum value for line meter
sets minimum value for line meter
show s minimum value for line meter
sets hysterese value for line meter
show s hysterese value for line meter
sets Port for Pow er Port Sw itching actions
show s Port for Pow er Port Sw itching actions
sets Port state for Pow er Port Sw itching actions
show s Port state for Pow er Port Sw itching acti-
ons
enters cmd group "modbus"
enables Modbus TCP support
show s if Modbus is enabled
sets Modbus TCP port
show s Modbus TCP port
enters cmd group "port"
sets port to new state
show s port state
sets several ports in one cmd - e.g. port all state
set "1,3,5" 1
show s all port states in 3 different view modes
start reset sequence for port
toggles port
starts batch mode for port
cancels batch mode
sets port label name
show s port label name
sets port coldstart initialization
show s port coldstart initialization
sets port init delay
show s port init delay
sets the individual port access code
show s the individual port access code
sets port repow er delay
show s port repow er delay
sets port reset duration
show s port reset duration
sets port w atchdog to on/off
show s port w atchdog state
sets port w atchdog mode
3