SRX 070ECM, SRX 120ECM, SRX 160ECM
9. Final installation
Fit casing cover following completion of installation
work. To do this, screw in the four fixing screws on the
underside of the device, see fig. 2.
10. Operation
The control panel is shown in fig. 3.
The individual elements have the following meaning:
A
– Operating mode button
B
– On/off indicator
C
– Cooling mode indicator
D
– Heating mode indicator
E
– Fan level button
F
– Low fan level indicator
G
– Medium fan level indicator
H
– High fan level indicator
J
– Thermostat setting wheel
K
– Cover for programming cassette slot
11. Heating mode
Press the
button once or several times until the yel-
low
indicator lights up.
Set the desired room temperature with the setting
wheel. Depending on the current room temperature
and the target temperature set on the thermostat, the
electronics calculate which of the three fan levels (fan
speeds) to use. The electronics select the required fan
level depending on the difference between the current
room temperature and the desired target temperature.
If necessary, the number of possible fan levels can be re-
duced. For instance, to limit the fan levels to a maximum
of 2, press the
button once or several times until the
red 2 indicator lights up. The temperature reduction is
forwarded to any downstream devices via the control
conductor.
Operation with a programming cassette or a timer can only
take place in automatic mode. If there is a control signal,
the red indicator lights
The set temperature on the thermostat must be higher
than the current room temperature.
The check valve closes only when the set "OFF" time
on the program cassette greater than 30 minutes (pro-
grammed delay).
12. Cooling mode
The cooling function is only available if cooling mode
has been set on the heat pump.
Press the button
once or several times until the yel-
low
indicator lights up.
Depending on the current room temperature and the
target temperature set on the thermostat, the
electronics calculate which of the three fan levels (fan
speeds) to use.
EN-20
up.
SRX_C_gb · 09/15/B
There are 3 possible fan levels. If necessary, the number
of possible fan levels can be reduced. For instance, to
limit the fan levels to a maximum of 2, press the
button once or several times until the red 2 indicator
lights up.
13. Operation with air/water heat pumps
When operating with an air/water heat pump, particularly
when temperatures are low outside, the heat pump's
buffer tank must be at a temperature of at least 14°C to en-
sure that the heat pump evaporator can defrost. You
should therefore ensure that thawing has taken place if
necessary before opening the valves to the heating circuit.
14. Fault indication
If the water temperature is too low, operation of the device
is interrupted and the red
case, check that the heating system and circulating pump
are operating correctly. For more information, please refer
to the "Troubleshooting" chapter 20.
15. Frost space protection
Frost protection is simply done in Standby mode, when
the temperature is below 7°C and the water above
15°C, the fan (and relay if activated) will switch on to try
and heat the room.
16. Cleaning outer surfaces
The heater must be switched off and cooled for clean-
ing. The surfaces of the heater can be cleaned by wip-
ing with a soft, damp cloth and then dried. Do not use
abrasive powder or furniture polish to clean as these
may damage the surface.
17. Maintenance – to be performed by a specialist
Dust or lint that collects inside the heater must be re-
moved at regular intervals.
To do this, disconnect the device from the power sup-
ply, loosen the 4 fixing screws on the underside of the
casing and carefully remove the casing cover. Remove
dirt with a soft brush or a vacuum cleaner.
Build-up of air in the heat exchanger can be remedied
by opening the bleeder valve (fig. 5c).
18. Warranty
Please contact your local dealer for information on cus-
tomer service and warranty conditions.
19. Disposal
The appliance should not be disposed of
with household waste, but should be taken
to your local recycling centre.