Herunterladen Inhalt Inhalt Diese Seite drucken

Hitachi Koki UC 14YFA Bedienungsanleitung Seite 7

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
English
(2) Regarding the temperature of the rechargeable battery.
The temperatures for rechargeable batteries are as shown in the table below, and batteries that have become
hot should be cooled for a while before being recharged.
Table 2
Rechargeable batteries
EB712S, EB7S
EB912S, EB9S, EB914, EB9B, EB9M, EB924
EB1212S, EB12S, EB1214L, EB12B, EB1220BL,
EB12M, EB1224
EB1412S, EB1414, EB14B, EB1424
EB9H, EB12H, EB1222HL, EB14H, EB930H,
EB1230H, EB1230HL, EB1430H
(3) Regarding recharging time
Table 3 shows the recharging time required according to the type of battery.
Table 3 Recharging time (approx. min.) at 20°C
Battery
voltage
1.2 – 1.4 Ah
(V)
EB712S
7.2 V
EB7S
EB912S
9.6 V
EB9S
EB914
EB1212S
12 V
EB12S
EB1214L
EB1412S
14.4 V
EB1414
: Ni-MH batteries
NOTE: The recharging time may vary according to the ambient temperature and the power supply voltage.
4. Disconnect the charger's power cord from the
receptacle.
5. Hold the charger firmly and pull out the battery.
NOTE
Be sure to pull out the battery from the charger
after use, and then keep it.
Regarding electric discharge in case of new batteries,
etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an
extended period is not activated, the electric
discharge might be low when using them the first
and second time. This is a temporary phenomenon,
and normal time required for recharging will be
restored by recharging the batteries 2-3 times.
How to make the batteries perform longer.
(1) Recharge the batteries before they become
completely exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery.
If you continue to use the tool and exhaust the
electric current, the battery may be damaged and
its life will become shorter.
6
2.0 Ah
EB9B
EB9M
30 min.
EB12B
50 min.
EB1220BL
EB12M
EB14B
Temperatures at which the battery can be recharged
Battery capacity (Ah)
2.2 Ah
EB9H
EB924
55 min.
EB12H
EB1224
EB1222HL
EB14H
EB1424
(2) Avoid recharging at high temperatures.
A rechargeable battery will be hot immediately after
use. If such a battery is recharged immediately after
use, its internal chemical substance will deteriorate,
and the battery life will be shortened. Leave the
battery and recharge it after it has cooled for a
while.
CAUTION
If the battery is charged while it is heated because
it has been left for a long time in a location subject
to direct sunlight or because the battery has just
been used, the pilot lamp of the charger lights up
green. In such a case, first let the battery cool, then
start charging.
When the pilot lamp flickers in red (at 0.2-seconds
intervals), check for and take out any foreign objects
in the charger's battery installation hole. If there are
no foreign objects, it is probable that the battery
or charger is malfunctioning. Take it to your
authorized Service Center.
Since the built-in micro computer takes about 3
seconds to confirm that the battery being charged
with UC14YFA is taken out, wait for a minimum of
3 seconds before reinserting it to continue charging.
If the battery is reinserted within 3 seconds, the
battery may not be properly charged.
-5°C – 60°C
0°C – 45°C
2.4 Ah
3.0 Ah
EB930H
60 min.
EB1230H
EB1230HL
EB1430H
70 min.

Werbung

Inhaltsverzeichnis
loading