H: When the
mark
appears, the childproof
lock has been activated.
I: When the SAVE
function is activated, the
heater will automatically
switch on or off in order
to remain within a
specified temperature
range.
4
48
f - 1
Faulty burner thermistor.
e - 2
Starting problems.
e - 5
Tipping-over protection.
e - 6
Poor burning.
e - 7
Room temperature
above 28°C.
e - 8
Defective booster.
e - 9
Air filter dirty; or
Fuel pump dirty.
The heater has been in operation
continuously for a period of 48 hours
and has turned itself off automatically.
-- : --
Out of fuel.
+
-- : --
Too little ventilation.
+
e - 1 1
Too little ventilation.
+
Always contact your dealer for any malfunctioning not listed above.
AUTOMATIC DEACTIVATION
This heater is fitted with a safety system that ensures that it switches off
automatically after 48 hours continuous operation. The following will then appear
in the display:
the
button
(see section D).
AUTOMATIC CLEANING MODE
When the heater has been burning continuously for two hours at its highest
setting, the burner will automatically start an autoclean procedure. The display
will show the autocleaningcode cl 05 running back to cl 00. The procedure takes 5
minutes, during which the heater will burn at its lowest setting, while the burner
autocleans. When the burner is clean again, the heater will automatically switch
back to the highest setting again.
I
CHILDPROOF LOCK
The childproof lock can be used to prevent children accidentally changing the
heater settings. When the heater is burning and the childproof lock is on, the heater
can only be switched off. Other functions are blocked then. If the heater has already
been switched off, the childproof lock also prevents accidental ignition of the
heater. Activate the childproof lock by pressing the appropriate key
down for more than 3 seconds. The KEY-LOCK indicator (
information display (Fig. H), indicating that the childproof lock has been activated.
Switch off the childproof lock by pressing the key
than 3 seconds once again.
J
THE CORRECT USE OF 'SAVE'
The 'SAVE' function allows you to limit the temperature. When this function is
activated, the heater will automatically switch off, when the room temperature
exceeds the set temperature by 3°C. Subsequently, when the room temperature has
dropped again to the set temperature, the heater will automatically switch on again.
Activate the 'SAVE' setting by pressing the appropriate
information display (Fig. I). Switch off the function by pressing the SAVE key once
again.
. If desired, you can switch the heater on again by pressing
Contact your dealer.
Contact your dealer.
Re-ignite the heater.
Contact your dealer.
If necessary,
re-ignite the heater.
Contact your dealer.
Clean filter.
Contact your dealer.
Switch the heater back on.
Refill removable tank.
Ventilate better.
Ventilate better.
and holding it
) will appear on the
and holding it down for more
key.
will display on the