Herunterladen Inhalt Inhalt Diese Seite drucken

Sharp PN-G655E Bedienungsanleitung Seite 34

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 39
Controlling the Monitor with a PC
Initialisation/Functional Restriction Setting (FUNCTION) menu
Function
ALL RESET
ADJUSTMENT LOCK
OSD DISPLAY
LED
Others
Function
SCREEN SIZE (PC)
SCREEN SIZE (AV)
VOLUME
MUTE
INFORMATION
MODEL
SERIAL NO
BRIGHT
TEMPERATURE SENSOR
TEMPERATURE ACQUISITION
CAUSE OF LAST STANDBY MODE
32
E
Command
Direction
Parameter
RSET
W
0
ALCK
WR
0-2
LOSD
WR
0-1
OFLD
WR
0-1
Command
Direction
Parameter
WIDE
WR
1-5
WIDE
WR
1-5
VOLM
WR
0-31
MUTE
WR
0-1
INF1
R
SRNO
R
VLMP
WR
0-31
DSTA
R
ERRT
R
STCA
W
0
R
Reply
Control/Response contents
0-2 0: OFF
0-1 0: ON, 1: OFF
0-1 0: ON, 1: OFF
Reply
Control/Response contents
1-5 1: WIDE, 2: NORMAL, 3: DotbyDot, 4: ZOOM1, 5: ZOOM2
1-5 1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: DotbyDot
0-31
0-1 0: OFF, 1: ON
Value
Value
0-31 Brightness
0 Internal temperature normal
1 Internal temperature abnormal (Standby mode)
2 Internal temperature abnormal (Temperature is normal now, but it was
abnormal during operation.)
3 Internal temperature abnormal (Brightness of the backlight decreases.)
4 Temperature sensor abnormal
Value Temperature at temperature sensors 1 through 3 are returned in the
following forms:
[Sensor 1], [Sensor 2], [Sensor 3]
Initialisation
0 No detectable error has occurred
1 Standby mode by POWER button
2 Main power "OFF" by the main power switch
3 Standby mode by RS-232C
4 Waiting mode by No Signal (Incl: VESA DPMS/DMPM)
6 Standby mode by abnormal temperature
8 Standby mode by SCHEDULE setting
*
No
Yes
Yes
Yes
*
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis