ENGLISH
Easy Setup Procedure
i Checking and storing the measurement
results
The measurement results displayed at "u Speaker measurements"
can be checked and stored in the memory.
1
D D H H
Press
to select the item, then press
Press ENTER to switch to the second screen.
2
ENTER
After checking, press
set.
Store:
All the settings are stored in the memory.
Cancel:
Cancel the auto setup settings.
3
When "Store" is selected:
F F
Press
.
• After the data is stored, the "Auto Setup / Room EQ"
screen appears automatically.
1
2
• When measurements have been made using the measurement
microphone, speakers with a built-in filter such as subwoofers
might be set with a value that differs from the physical distance
because of the internal electrical delay.
NOTE:
• Do not turn off the power while the data is being stored.
Error messages
An error message is displayed if the measurements could not be completed automatically due to the speaker layout, the measuring
environment, etc. Please check the following matters, reset the pertinent items, and measure again.
Be sure to turn off the AVR-2807's power before checking the speaker connections.
ENTER
.
Example
D D H H
, then press
to
Cause
q The
speakers
required
for
producing
reproduction have not been detected.
If multiple errors occur, press F F G G to check the
contents.
w The speaker polarity is connected in reverse.
If multiple errors occur, press F F G G to check the
contents.
e There is too much ambient noise in the room and the
measurements cannot be made accurately.
r The sound level that is output from the speakers and/or
subwoofer is too low.
t The measurement microphone is not connected, or all
of speakers have not been detected.
12
ENGLISH
Easy Setup Procedure
Measures
• Check that the pertinent speakers are properly
suitable
connected.
• Check the polarity of the pertinent speakers.
• For some speakers, the screen below may be
displayed even though the speakers are
properly connected.
If so, select "Skip
".
0
• Either turn off the power of the device that
generated the noise during the measurements
or move the device away.
• Try again at a time when it is quieter.
• Check the placement and orientation of the
loudspeakers.
• Adjust the subwoofer's output level.
• Connect the attached setup microphone to
< SETUP MIC > .
• Check the speaker connection.