GB
22. Accessories
The CLICK&PAINT SYSTEM with additional spray attachments and accessories offers
the right tool for each work.
Further information about the WAGNER range of products for renovating is available
under www.wagner-group.com
23. Correction of Malfunctions
Problem
No coating material
emerges from the
nozzle
Coating material
drips from the
nozzle
Atomisation too
coarse
Spray jet pulsates
34
Cause
•
Nozzle clogged
•
Feed tube clogged
•
Material volume setting turned
too far to the left (-)
•
Feed tube loose
•
No pressure build-up in container
•
Ventilating bore (Fig. 12, 1)
clogged
•
Nozzle loose
•
Nozzle worn
•
Nozzle seal is missing or worn
•
Coating material assembly at air
cap, nozzle or needle
•
Coating material too thick
•
Material volume too large
Material volume adjusting screw
turned too far to the right (+)
•
Nozzle contaminated
•
Air filter heavily soiled
•
Too little pressure build-up in
container
•
Amount of air too low
•
Coating material in container
running out
•
Air filter heavily soiled
•
Nozzle seal is missing or worn
W 570 Flexio
Remedy
➞ Clean
➞ Clean
➞ Turn to the right (+)
➞ Insert
➞ Tighten container
➞ Clean
➞ Tighten
➞ Change
➞ Insert an intact nozzle
seal
➞ Clean
➞ Dilute
➞ Turn material volume
adjusting screw to the
left (-)
➞ Clean
➞ Change
➞ Tighten container
➞ Increase air quantity
(Level: Wall & Ceiling
)
➞ Refill
➞ Change
➞ Insert an intact nozzle
seal