Ambient conditions
Climatic conditions
Storage
Transport
Operation
Site altitude
Electrical
Mains connection AC system
Max. mains voltage range
E82MV251... and E82MV371...
E82MV551... to E82MV222...
E82MV302... to E82MV752...
Mains frequency
Mechanical
Vibration resistance
2
(9.81 m/s
Mounting conditions
Mounting position
Free spacess
Free spaces with fan
module E82ZMV
Dimensions,
Weights
EDK82MV752 DE/EN/FR 7.2
IEC/EN 60721−3−1
IEC/EN 60721−3−2
IEC/EN 60721−3−3
Germanischer Lloyd
= 1 g)
l
General
conditions
All mounting positions and mounting alignments are permitted
Above:
To the sides:
for fan exchange:
Note regarding the operation with fan module E82ZMV:
The fan module must always be used in the case of
l
motec wall mounting
l
operation without current derating with self−ventilated Lenze motors or Lenze
geared motors
l
operation with non−Lenze motors
^ Chapter "Mechanical installation"
^ Chapter "Technical data", "Operation with rated power" or "Operation with
increased rated power"
l
Technical data
General data and operating conditions
1K3 (−25 ... +60 °C)
2K3 (−25 ... +70 °C)
3K3 (−20 ... +60 °C)
At temperatures > +40 °C, reduce the rated output current by
2.5 %/°C.
< 4000 m amsl
Reduce rated output current by 5 %/ 1000 m above
1000 m amsl.
1/N/PE or 2/PE 180 V − 0 % ... 264 V + 0 %
3/PE 320 V − 0 % ... 550 V + 0 %
3/PE 320 V − 0 % ... 550 V + 0 %
45 Hz − 0 % ... 65 Hz + 0 %
Acceleration resistant up to 2 g
100 mm
100 mm
250 mm