Product Characteristics

4.7 SCALANCE X005 Technical Specifications

Port status indicator (green/yellow LEDs)
The status of the ports is indicated by five LEDs:
Status
Port 1 to 5 LED lit green
Port 1 to 5 LED lit yellow
Port 1 to 5 LED flashes yellow
4.7 SCALANCE X005 Technical Specifications
Technical Specifications of SCALANCE X005
Ports
Attachment of DTEs or network components over
twisted pair
Connector for power supply
Electrical Data
Power supply
Power loss at DC 24 V (typ.)
Current consumption at rated voltage (typ.)
Overvoltage protection at input
Permitted Cable Lengths
Connection over Industrial Ethernet FC TP
cables
0 –100 m
0 –85 m
Aging time
4-6
Meaning
TP link exists, no data reception
TP link exists, data received at TP port
Test phase during power on
5xRJ-45 sockets with MDI-X pinning 10/100
Mbps (half/ full duplex)
1 x 2-pin plug-in terminal block
Power supply DC 18 .. 32 V
safety extra-low voltage (SELV)
2 W
80 mA
PTC resetable fuse (0.5 A / 60 V)
Industrial Ethernet FC TP standard cable with IE
FC RJ-45 plug 180
or
over Industrial Ethernet FC outlet RJ-45 with 0 -
90 m Industrial Ethernet FC TP standard cable +
10 m TP cord
Industrial Ethernet FC TP marine/trailing cable
with IE FC RJ-45 plug 180
or
0 - 75 m Industrial Ethernet FC TP marine/trailing
cable + 10 m TP cord
375 seconds
Industrial Ethernet SCALANCE X005
Commissioning Manual, A2B00051528A