Addressing

Each device occupies 1 channel. To ensure that the control signals are properly directed to each device, the
device requires adressing. This is to be done for every single device by changing the DIP switches as set out
in this table.
The starting address is defined as the first channel from which the device will respond to the controller.
Please make sure that you don't have any overlapping channels in order to control each device correctly and
independently from any other device on the DMX data link. If two, three or more device are addressed
similarly, they will work similarly.
Occupation of the DIP-switches:
Setting the DMX-
starting address:
Device number
& channels
Device 1 - channel 1
Device 2 - channel 2
Device 3 - channel 3
Device 4 - channel 4
Device 5 - channel 5
Controlling:
After having addressed all devices, you may now start operating these via your controller.

DMX-protocol

Channel 1 – Fog volume
DMX-value:
0 - 255
Gradual adjustment of the fog volume from 0 to 100 %

CLEANING AND MAINTENANCE

We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
Clean the escape nozzle frequently from smoke fluid residues.

Cleaning the heating element

The heating element should regularly be cleaned every 30 operational hours in order to avoid clogging. Use
smoke machine cleaner available at your dealer.
Procedure:
Fill cleaner into empty tank. Run the machine several times in a well-ventilated room only. The number of
repititions depends on the pollution level of the vaporizing elements. After use clean all remaining cleaner
and rinse the tank thoroughly.
The EUROLITE smoke fluids we recommend are non-hazardous to the environment and can be disposed of
via the sewage system.
There are no servicable parts inside the device except for the fuse. Maintenance and service operations are
only to be carried out by authorized dealers.
1
DIP-switch no.
1
Starting address
On
Off
Off
On
Off
On
Off
On
Off
On
Off
Volume (%)
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
2
3
4
5
6
2
4
8
16
32
23/44
7
8
9
64 128 256
51701971_V_1_0.DOC

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis