SinePower
9

Connecting the inverter

9.1

General instructions

!
WARNING!
• The inverter may only be connected by a suitably qualified techni-
cian. The following information is intended for technicians who are
familiar with the guidelines and safety precautions to be applied.
• For vehicles in which the positive terminal of the battery is connected
with the chassis the inverter must not be installed.
• If you do not fit a fuse to the positive cable, the cables can over-
load, which might result in a fire.
• Reversed polarity can damage the inverter.
• MSI900, MSI1300, MSI1800: The inverter must not be used in a
ring main, but only used for supplying individual devices with elec-
tricity. These devices must be plugged directly into the inverter, or
connected to the inverter using a sheathed extension cable manu-
factured for this purpose.
• When installed in vehicles or boats, the inverter must be connected to the chassis
or earth.
• When setting up a socket distribution circuit (mains set up), comply with
VDE 0100.
• Only use copper cables.
• Keep the cables as short as possible (< 1.8 m).
• Keep to the required cable cross section and fit a cable fuse (fig. 9 3, page 6) as
close as possible to the battery in the positive cable (see Table).
Device
MSI912
MSI924
MSI1312
MSI1324
MSI1812/MSI1812T/
MSI1812TOE
MSI1824/MSI1824T
EN
Required cable
cross section
25 mm²
25 mm²
35 mm²
35 mm²
35 mm²
35 mm²
Connecting the inverter
Cable fuse
(fig. 9 3, page 6)
115 A
75 A
170 A
85 A
228 A
115 A
21