Herunterladen Inhalt Inhalt Diese Seite drucken

Trouble Shooting; Spare Parts Order - Parkside PHD 150 B2 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für PHD 150 B2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 75
GB

Trouble shooting

Problem
Possible cause
ON / OFF switch (10) is
turned off
Pressure
Damaged power supply
cleaner is not
cable (6)
operating
Mains fault
Air trapped in the pressure
Pressure clean-
cleaner
er does not
generate any
Drop in the water mains
pressure
pressure
Severe pres-
High-pressure nozzle (17)
sure fluctua-
is dirty
tions
Connections not fitted cor-
rectly
Leaks in the
water system
Water connection (9) leaks

Spare Parts Order

When buying parts for the pressure cleaner, use the service address given.
Please enter your machine type and the item number of the part you are ordering.
Item
Description ....................................................... Product No.
1
Jet gun .......................................................................... 91097399
3
High-pressure hose .......................................................... 91097400
13
Quick connector for garden hose adaptor ......................... 91097401
17
Turbo dirt blaster ............................................................ 91097403
18
Standard Vario nozzle..................................................... 91097404
19
Rotating wash brush ........................................................ 91097405
9
Water connection w/ strainer frame.................................. 91097408
14
Remedy
Check ON / OFF switch (10)
Switch off the equipment and disconnect
from the mains. Check power supply
cable (6) for damage. If necessary have
the power supply cable (6) replaced by
a qualified electrician.
Check the electrical system for conform-
ity with the data on the rating plate.
Switch on the equipment with the jet gun
and with no nozzle until bubble-free wa-
ter comes out.
Check the water mains.
Rinse the high-pressure nozzle (17) with
water. If necessary clean the nozzle hole
with a needle.
Switch off the equipment and disconnect
from the mains. Reconnect the equipment
to the water pipes (cf. "Initial Operation/
Set-Up")
Switch off the equipment and disconnect
from the mains. Replace the water con-
nection (9) inc. gasket (cf. "Spare Parts")

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis