Fehler! Verwenden Sie die Registerkarte 'Start', um Heading 1 dem Text zuzuweisen, der
hier angezeigt werden soll.
Flarm port can be also configured on newer types of LX9000D. It can be enabled
in Setup-NMEA Output with selecting FLARM
5.1.7.2 PDA port (RJ45
Newer types of units have also expansion port called PDA (RJ45). On this port can be
connected different types of PDA devices.
Pin number
1,2
3
4
5
6
7,8
RJ45 plug is NOT designed in accordance with IGC standard. It can be used only
with dedicated cable. Do not plug unknown cable to it as it may damage unit or
PDA port.
On PDA port can be connected following connection cables:
Device
OUDIE
Generic RS232 with female DB9
IPAQ 310/314
IPAQ 38/39xx/47xx
1 2 3 4 5 6 7 8
Pin numbers
Description
Ground
(output) Transmit from LXNAV RS232 (e.g. Computer, IPAQ38/39xx)
(input) Receive to LXNAV RS232 (e.g. Computer, IPAQ38/39xx)
(output) Transmit from LXNAV V7 LV-TTL (3.3V) (e.g. Oudie, HP302,
HP31x)
(input) Receive to LXNAV LV-TTL (3.3V) (e.g. Oudie, HP302, HP31x)
5V OUTPUT (maximum 1A)
Page 38 of 66
Version 1.0, June 2015
8 7 6 5 4 3 2 1
Pin numbers
Cable code
CC-NP-OUDIE1
CC-NP-232
CC-NP-IPAQ310
CC-NP-38