GB
s t ar tup
4.3
cOnnectIOn tO tHe mAInS netWORk
Connection must always be carried out via
an appropriately grounded safety outlet with
residual-current-operated circuit-breaker.
Before connecting the unit to the mains supply, ensure that
the line voltage matches that specified on the unit's rating
plate.
4.4
cleAnInG PReSeRVInG AGent WHen
StARtInG-uP OF OPeRAtIOn InItIAlly
1. Immerse the suction system into a container filled with a
suitable cleaning agent (recommendation: water).
2. Switch on unit.
3. Turn the pressure regulating knob (1) to the right until
the stop is reached.
4. Open relief valve (2)
valve position
(circulation)
5. Wait until cleaning agent is emitted from the return hose.
6. Turn the pressure regulating knob (1) back approx. one
rotation.
7. Close relief valve (2)
valve position
(spraying), pressure is rising up inside
the high pressure hose (visible at pressure gauge)
8. Point the tip of the spray gun into an open collecting con-
tainer and pull the trigger guard at the spray gun.
9. The pressure is increased by turning the pressure regulat-
ing knob (1) to the right. Set approx. 10 MPa at the pres-
sure gauge.
10. Spray the cleaning agent out of the unit for approx.
1 - 2 min. (~5 litres) into the open collecting container.
4.5
VentIlAte unIt (HydRAulIc SyStem) IF tHe
SOund OF Inlet VAlVe IS nOt AudIBle
1. Switch on the unit.
2. Turn pressure regulating knob (1) three revolutions to
the left.
3. Open relief valve (2)
valve position
(circulation)
The hydraulic system is ventilated. Leave the unit on for
two or three minutes.
4. Then turn pressure regulating knob (1) to the right until
stop.
5. Press inlet valve pusher (4).
Sound of the inlet valve is audible.
6. If not, repeat points 2 and 4
38
4.6
tAkInG tHe unIt IntO OPeRAtIOn WItH
cOAtInG mAteRIAl
1. Immerse the suction system into a container filled with
coating material.
2. Press inlet valve pusher (4) several times to release pos-
sibly clogged inlet valve
3. Open relief valve (2)
valve position
(circulation)
4. Switch on unit.
5. Turn the pressure regulating knob (1) to the right until
the stop is reached.
When the noise of the valves changes, the unit is bled and
takes in coating material.
6. If coating material exits from the return hose, turn the
pressure regulating knob (1) back approx. 1 rotation.
7. Close relief valve (2)
valve position
(spraying), pressure is rising up inside
the high pressure hose (visible at pressure gauge)
8. Pull of the spray gun and spray into an open collecting
container in order to remove the remaining cleaning
agent from the unit. When coating materials exits from
the tip, close the spray gun.
9. Pull of the spray gun and adjust the spraying pressure by
turning the pressure regulating knob (1).
10. The unit is ready to spray.
Super Finish 7000
3
1
4
2