4. With the G-LCD panel's screen center as refernce, adjust the R-LCD and B-LCD panels.
5. Finally tighten up the convergence lock screw "d".
Notes :
1 The eccentric cam is used for convergence adjustment.
This means that the cam's turning and the linear movement are not always uniform.
2 This model is not equipped with the LCD image adjustment mechanism. This is because the cross-dichroic
prism is used for image formation. When the LCD panels all get into best focus, the images are almost
completely converged.
Convergence and Focus Adjustments Mechanism
TOP VIEW
B-LCD
SIDE VIEW (from inside)
Lock screw "d"
R·B-LCD
Lock screw "a"
R-LCD
Notch and
hole "c"
Lock screw "c"
G-LCD
Lock screw "b"
Notch and
hole "b"
Lock screw "c"
Notch and hole "c"
Notch and hole "a"
Lock screw "d"
R·B-LCD panel
mounting screws
(four screws)
21
SIDE VIEW
G-LCD
SIDE VIEW (from outside)
Eccentric cam
(Y direction adjustment)
XG-C40XU/XE
G-LCD panel
mounting screws
(four screws)
Eccentric cam
(X direction adjustment)
Eccentric cam
(θZ direction adjustment)