Connection plan SmartKey code keypad with integrated reader
ye
Coil 1
gn
Coil 2
rd
Voltage 12 V
bl
Buzzer activation
pk
Activation LED red
bn
Activation LED green
pur
Activation LED yellow
gr-pk
T5
bn-gn
T6
rd-bl
T7
wh-gn
T4
wh
T1
bl
T2
gr
T3
You will find connections, start-up, operation for connection to the SE 210 LSN and
SE 310 LSN in the Installation manual SmartKey arming device.
Depending on the connection to other systems (excluding SmartKey control units),
series resistance for the LEDs must be used to limit the current!
WARNING
ST1
11
SU1
D1
1N4448
ST1
8
ST1
9
ST1
10
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1 connector for socket board
- 8 -
L1: air coil
81 coils
L 1
Wire diameter 0.16 mm
548uH
insulated with lacquer
middle coil diameter 37 mm
+
SU 1:
Buzzer
Piezo buzzer F/CM 12PT
WPB-DIGISOUND
Membrane keypad
LD3
LED yellow: I
ye
LD2
LED green: I
gn
LED red: low current LED
LD1
rd
1
4
7
C
≈ 20 mA
F
≈ 20 mA
F
2
3
5
6
8
9
0
610-4.998.115.270
A4 01.04.2004