C
D
R
S
26
→
Insert the position feedback
housing into the duplication
system "D" setting the cable
gland in the direction desired
and making sure, on a mecha-
nical contact version, that you
do not damage the contact
levers on the switches.
→
Fasten the housing and the
duplication system by tigh-
tening the cone point set screw
"C" using a hexagonal male
spanner.
→
Unscrew the cover "R" on the
position feedback.
→
Unscrew the cable gland "S".
→
Thread the cable through the
cable gland.
→
Wire according to the wiring
diagram for your version of the
1062: See Chapter 8..
→
Fasten the cable gland to
ensure tightness of the product.
English
Type 1062
Assembly