Trouble Shooting

Problem
Device does not start
Device runs with
interruptions
Blades become hot
24
Possible cause
Mains voltage not on
On/Off switch (
defective
Worn carbon brushes
Defective motor
Power cable is damaged
Internal loose electrical
connection
On/Off switch (
defective
Blades (
2) are blunt
Blades (
2) are notched
Too much friction due to
lack of lubrication

Fault correction

Check plug socket, cable, line
and plug, where appropriate,
have repaired through electrical
specialist
7)
Repair by Service Centre
Check the cable and have it
changed by the Service Centre if
necessary
Repair by Service Centre
7)
Have the blades sharpened or
replaced (Service Centre)
Have the blades checked or
replaced (Service Centre)
Oil the blades (see "Maintenance/
Cleaning"