Herunterladen Inhalt Inhalt Diese Seite drucken

Pneumatic Connection - bürkert 2100 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für 2100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

8.4.
pneumatic connection
DAnger!
danger – high pressure in the equipment!
Before loosening the lines and valves, turn off the pressure and
vent the lines.
wArning!
risk of injury from unsuitable connection hoses!
Hoses which cannot withstand the pressure and temperature
range may result in hazardous situations.
Use only hoses which are authorised for the indicated pressure
and temperature range.
Observe the data sheet specifications from the hose
manufacturers.
For control function i – danger if pilot pressure fails!
For control function I control and resetting occur pneumatically. If
the pressure fails, no defined position is reached.
To ensure a controlled restart, first pressurize the device with
pilot pressure, then switch on the medium.
26
english
Type 2100
Installation
8.4.1.
connection of the control Medium
If the position of the control air connections for installation
of the hoses is unfavourable, these can be aligned step-
lessly by rotating the drive through 360°.
The procedure is described in the chapter entitled "8.3.3.
Rotating the Actuator".
Control functions a and B:
Connect the control medium to the
(see "Fig. 17: Pneumatic Connection").
Silencer
For the versions with a plug-in connection the silencer for reducing
the exhaust air noise is supplied loose.
Plug the silencer into
the free air discharge connection 2 (see
"Fig. 17: Pneumatic Connection").
If used in an aggressive environment, we recommend
conveying all free pneumatic connections into a neutral
atmosphere with the aid of a pneumatic hose.
pilot air port 1 of the actuator

Werbung