C) Operation - Renkforce 1210395 Bedienungsanleitung

Tiefbrunnenpumpe 900 w
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

• Ensure that electrical plug connections are in flooding-safe areas; otherwise, there is a danger
to life from electric shock! If required, use suitable protective housings for the plug connec-
tions.
• Protect the mains plug from wetness! Never touch the mains plug with wet hands! There is
danger to life from electric shock!
• The mains cable or mains plug must not be cut off.

c) Operation

• The product must not be operated by children or teens. This also applies regarding persons
who are not familiar with these operating instructions. Persons with limited physical or mental
capacities must only use the product if supervised and instructed by a person responsible for
them.
• Only clear, clean fresh water with a temperature of no more than +35 °C must be conveyed.
• The conveyed liquid must be clean. The build of the deep-well pump permits contamination
only up to a grain size of 1.5 mm.
• The product is not suitable for conveying potable water or food.
• The product is not suitable for conveying corrosive/caustic, flammable or explosive liquids
(e.g. gasoline, fuel oil, nitro diluent), grease, oils, salt water or sewage from toilets.
• The mains socket to which the deep-well pump is connected must be easily accessible. The
mains cable must point downwards from the mains socket so that the water running back at
the cable cannot enter the mains socket.
• If the deep-well pump is to be operated, e.g., in a well, it must be suitably attached, e.g. with
a rope. The rope must be able to hold at least 3 times the weight of the deep-well pump for
reasons of safety. Never attach the deep-well pump via its mains cable; also never use the
mains cable to carry, hold or submerse the deep-well pump!
• The product is not protected against running dry.
• The product must not be operated unsupervised.
• The product must not work in permanent operation.
• No persons must be present in the conveyed medium during operation.
• The product must not be operated in or close to explosive liquids or gases; there is a danger of
explosion!
• Consequential damage caused by malfunction or interference at the deep-well pump must be
prevented by suitable measures (e.g. water level indicator, sensors, alarm devices, backup
pump, etc.).
• The product is only suitable for use in temperate, not tropical, climates.
• Do not shut off the outlet side of the deep-well pump when it is in operation.
Use, e.g., a corresponding pressure switch to switch off power supply to the deep-well pump
in time.