5. Operating Instructions
Refer to the illustrations on page 2 of this manual.
Flying insects, attracted by the UV light [A], land on the glue board placed inside the housing, get
stuck and die from dehydration.
a. Mounting
Determine a proper mounting location. The insect killer should be mounted in a rather dark place
at a height of about 2m (out of reach of children). The device is not suitable to be used in a
garage, stable or similar (semi-outdoor) environment.
Note: a mains outlet is required near the mounting location.
The GIK13 can be used freestanding or hanging from the ceiling (chains included).
When suspending from the ceiling, mount 2 hooks (not incl.) to the ceiling. Make sure the ceiling
is strong enough to carry the weight of the GIK13. Attach the chains to the hooks and the other
ends to the suspension points of the GIK13.
b. Glue board
Remove the protective cover of the glue board and slide it with the sticky side facing the UV-
lamps in the housing.
Replace the glue board on a regular basis. Spare glue board: GIK13GB (5 pcs).
c.
Switching on/off
Connect the included power cable to the power socket [D].
Plug the other end of the cable into a suitable mains outlet to switch on the lamps.
To switch off the lamps, simply unplug the power cable from the mains.
d. Cleaning the device
Unplug the device from the mains.
Clean the insect killer regularly with a moist soft cloth. Do not use alcohol, abrasives or solvents.
Do not submerge into any liquid.
Make sure no dust accumulates on the UV lamps as this will greatly reduce their effectiveness.
e. replacing lamps and starters (refer to the illustrations on page 2)
When the lamp is worn, it must be replaced with a similar type (see technical specifications).
Unplug the device from the mains.
Gently rotate the lamp 90° (its pins must be lined up with the grooves on top of the fittings) and
pull the lamp upwards.
Note: it is strongly recommended to wear protective gloves when handling the lamps.
Insert a new lamp in the fittings and rotate it 90° to secure it.
To replace a starter [C], turn the starter a quarter turn anticlockwise and pull it out of the
socket. Insert a new starter with the same specifications (220-240V~, 4-22W) into the socket
and turn it a quarter turn clockwise to secure it.
Reconnect the device to the mains power outlet.
Dispose of worn or broken lamps in accordance with local regulations.

6. Technical specifications

input voltage
effective area
dimensions
weight
lamp
spare glue board
Use this device with original accessories only. Velleman nv cannot be held responsible in the
event of damage or injury resulted from (incorrect) use of this device. For more info
concerning this product, please visit our website www.perel.eu. The information in this
manual is subject to change without prior notice.
© COPYRIGHT NOTICE
This manual is copyrighted. The copyright to this manual is owned by Velleman nv. All worldwide rights reserved.
No part of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise without
the prior written consent of the copyright holder.
02.12.2010
GIK13
230VAC / 50Hz
100m²
Ø195 x 555mm
3.3kg
UV tube 2 x 15W (spare lamp: GIK09LAMP)
GIK13GB
4