Operation
Why convection? Perfect heat distribution
Convection technology offers a uniform heat distribution over the whole working area of the
Preheater. This gradual heating system reduces the risk of thermal stress on the PCb.
Profiles by Temperature
The usual way to run a profile is using the Thermocouple (TC) connected to the Control Input of the
console. JbC offers 3 predefined profiles (JbCset) and 20 profiles ready for you to personalize.
JBCset profiles
There are 3 profiles predefined by JbC: a, b and C. The difference between them is the number
of steps: 2, 3 or 4. The thicker your PCb is and the more layers it contains, the more steps are
needed to obtain a gradual warming.
These profiles are not modifiable but they can be used as a template to create your own profiles.
JBCset A
2 steps
PCB
FR4 1,6mm thick
reference
and 2 layers.
specifications:
Profiles set using the low position of the PHB-SA Support (28 mm in height between the PCB and the heating area).
User profiles
You can create your own profiles from the JbCset profiles. On the work screen of the profile,
press the Enter button and choose the option Edit profile.
For repetitive jobs we recommend running profiles without the Thermocouple (TC). Once
any profile has been run to the end, the system has all the process data which you can save.
Once it is saved, you can run this profile without connecting the Thermocouple (TC). The
heating process will the same as long as the same working conditions are respected.
Power or Temperature Modes
The unit works at the selected power or temperature during the defined time. These parameters
can be modified from the work screen by pressing the Enter button and the Edit parameters menu.
To see the current temperature you must plug the Thermocouple (TC) into the Control connector.
4
JBCset B
JBCset C
3 steps
4 steps
FR4 1,6mm thick
FR4 2,2mm thick
and 6 layers.
and 6 layers.
Recommended Guidelines
1. Place the Thermocouple (TC) as near as possible to the component being worked on.
Auxiliary Thermocouple (TC)
2. If there are any sensitive components, use the auxiliary Thermocouple as protection.
You can select the protection temperature in Station settings. If the selected temperature is
reached, the Heater Unit will stop the process and a warning message will be shown.
3. IPC* does not recommend exceeding ramp-up rates over 3 - 4 °C / sec (5 - 7 °F / sec) so as to
reduce the risk of thermal stress on the PCb.
* IPC was founded in the U.S. in 1957 as the Institute for Printed Circuits and is committed to becoming the
most recognized international industry association for the electronics manufacturing industry.
w w w.jbctools.com
Fix the TC with Kapton Tape
5