Operating mode
Measuring range
AC Volt
4 V
40 V
400 V
750 V
Overload protection 1000 V, input resistance: 10 MW
True relative value measuring from 10 to 100% of the measuring range
Alternate current frequency: 45 Hz to 1 KHz
Crest factor max. 3
DC Ampere
400 µA
4000 µA
40 mA
400 mA
10 A
Overload protection µA/mA 0.5A 250 V swift tripping fuse
10 A
10 A 250 V swift tripping fuse
Measuring duration in the 10 A range:
AC Ampere
400 µA
4000 µA
40 mA
400 mA
10 A
Overload protection µA/mA
0.5A 250 V swift tripping fuse
10 A
10 A 250 V swift tripping fuse
Measuring duration in the 10 A range:
True relative value measuring from 10 to 100% of the measuring range
Alternate current frequency: 45 Hz to 1 KHz
Crest factor max. 3
Resistance
400 Ω
4 kΩ
40 kΩ
400 kΩ
4 kΩ
40 MΩ
Overload protection 1000 V
Continuity tester: acoustic signal with resistances of <50 Ω, test voltage: -1,2V
Diode test
Test voltage max. 2.8 V, test voltage max. 1 mA
46
Accuracy
Resolution:
+/-(1% + 4 dgt)
0,001 V
+/-(1% + 4 dgt)
0.01 V
+/-(1% + 4 dgt)
0,1 V
+/-(1.5% + 4 dgt)
1 V
+/-(0,5%+10)
0,01 µA
+/-(0,5%+10)
0,1 µA
+/-(0,5%+10)
0,001 mA
+/-(0,8%+10)
0,01mA
+/-(1,5%+20)
0,001 A
0 to </=5 A permanent measuring,
> 5A max. 10 sec. with 15 min. break
+/-(1,2%+4)
0,1 µA
+/-(1,2%+4)
1 µA
+/-(1,2%+4)
0,01 mA
+/-(1,2%+4)
0,1mA
+/-(2,0%+3)
0,01 A
0 to </=5 A permanent measuring,
> 5A max. 10 sec. with 15 min. break
+/-(0.8% + 10 dgt) 0,01 Ω
+/-(0.5% + 10 dgt) 0.0001 kΩ
+/-(0.5% + 10 dgt) 0,001 kΩ
+/-(0.5% + 10 dgt) 0,01 kΩ
+/-(0.5% + 10 dgt) 0.0001 MΩ
+/-(1.5% + 20 dgt) 0.001 MΩ

Delivery Scope

Multimeter
Block battery 9V
K-type thermal sensor (up to max. 230°C)
Multi-purpose plug for the K-type thermal sensor
Safety measuring cables red and black
Crocodile clamp
Spare fuse 0.5 A 250 V swift tripping 5x20 mm
Spare fuse 10 A 250 V swift tripping 5x20 mm
Operating instructions

Handling and Commissioning

Display and Symbols
HOLD
stands for data hold, the measuring value is held (e.g. for logging) until
you press the "HOLD" button again or turn the multimeter off.
stands for relative value measuring
Auto range
stands for "Automatic measuring range selection"
OL
stands for overload = the measuring range was exceeded
Battery change symbol; change batteries immediately in order to pre-
vent measuring errors!
Symbol for diode test
Symbol for the acoustic continuity test
TRUE RMS
Indicator for the real relative value measuring in the AC measuring range
AC
= switchover value for voltage and current
DC
= direct value for voltage and current
mV
= millivolt (exp.–3)
V
= Volt (unit of electric voltage)
A
= Ampere (unit of electric current)
mA
= milliampere (exp.–3)
µA
= microampere (exp.-6)
Hz
= Hertz (frequency unit)
kHz
= Kilohertz (exp.3)
MHz
= Megahertz (exp.6)
= Ohm (unit of electric resistance)
kΩ
= Kiloohm (exp.3)
MΩ
= Megaohm (exp.6)
31

Werbung

loading