9.4 Connecting to earth (Fig. 3)
The generator must be earthed to prevent an electric
shock from electrical equipment. Connect a piece of
cable between the earth connection (4) on the gene-
rator and an external earth point.

10. Maintenance

Remove dust and dirt from the machine at regular
intervals. The best tools for cleaning are a fine
brush or a cloth
Do not use any caustic substances to clean the
plastic
Take the petrol mixture out of the generator if you
do not intend to use the generator for a lengthy
period of time
Important: Switch off the machine immediately
and contact your service station:
In the event of unusual vibrations or noise
If the engine appears to be overloaded or misfires

11. TECHNICAL DATA

Generator
Protection type:
Continuous power S1:
Maximum power S2 5 min.:
Rated voltage:
Rated current:
Frequency:
Drive engine design
Displacement
Max. power:
Fuel:
Tank capacity:
Weight:
Sound power level L WA :
Sound pressure level L WM :
Spark plug:
Operating mode S1 (continuous operation)
The machine can be continuously operated with the
quoted power output.
Operating mode S2 (temporary operation)
The machine may be temporarily operated with the
quoted power output (5 min). Afterwards the machine
must be stopped for a while to prevent it from
overheating (5 min).
12. Changing the oil and checking the
oil level (before using the machine)
The engine oil is best changed when the engine is at
working temperature.
Only use engine oil (15W40).
Place the generator on a slightly inclined surface
so that the oil drain plug is at the lower end.
Open the oil filler plug.
Open the oil drain plug and let the hot engine oil
drain out into a drip tray.
After the old oil has drained out, close the oil drain
plug and place the generator on a level surface
again
Fill in engine oil up to the top mark on the oil dip
stick (approx. 0,6 liters).
Important: Do not screw in the oil dip stick – only
insert it.
Dispose of the old oil properly.
Synchronous
IP 23
13. Cleaning the air filter
2000 W
2200 W
Remove the cover from the air filter.
Now you can remove the filter elements.
2x230 V
Do not use abrasive cleaning agents or petrol to
8,7 A
clean the elements.
50 Hz
Clean the elements by tapping on a flat surface.
4-stroke, air-cooled
196 cm
3
4,77 kW / 6,5 PS
14.Ordering replacement parts
normal unleaded petrol
Please quote the following data when ordering repla-
15,0 l
cement parts:
Type of machine
44 kg
Article number of the machine
93 dB(A)
Identification number of the machine
91 dB(A)
Replacement part number of the part required
NGK BPR5ES