Manual override function
If a mains switch is installed in the mains supply lead,
the following functions are provided in addition to
simply switching light ON and OFF:
Manual override
1) Activate manual override:
Switch OFF and ON twice. The light is set to stay ON
for 4 hours (blue LED lights up behind lower glass
cover). Then it returns automatically to sensor mode
(blue LED OFF).
2) Deactivate manual override:
Switch OFF and ON once. Light goes out or switches
to sensor mode.
Important:
The switch should be actuated in rapid succession
(in the 0.2 –1 sec. range).
What is soft light start?
The SensorLight features a soft light start function.
This means that when turned ON, the light is not
switched directly to maximum output but gradually
builds up brightness to 100 % within the space of a
second. Brightness is also gradually reduced when
the light is switched OFF.
What is basic lighting level?
Basic lighting level provides continuous night-time
illumination at approx. 10 % light output. The light
only switches to maximum output of 100 % (for the
time selected, see Switch-off delay
) in response to
movement in the detection zone. The light then
returns to basic lighting level (approx. 10 %).
Note: Depending on the local power grid, the LED's
may flicker slightly when dimmed. This is not a prod-
uct defect and no reason for complaint.
Declaration of Conformity
This product meets:
- Low Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
- RoHS Directive 2011/65/EC
- WEEE Directive 2012/19/EC
Functional Warranty
This STEINEL product has been manufactured with
utmost care, tested for proper operation and safety
and then subjected to random sample inspection.
STEINEL guarantees that it is in perfect condition and
proper working order. The warranty period is 36
months and starts on the date of sale to the consumer.
We will remedy defects caused by material flaws or
manufacturing faults. The warranty will be met by
repair or replacement of the defective parts at our own
discretion. The warranty shall not cover damage to
wear parts, damage or defects caused by improper
treatment or maintenance. Further consequential
damage to other objects shall be excluded.
Claims under the warranty will only be accepted if
the unit is sent fully assembled and well-packed with
a brief description of the fault, a receipt or invoice
(date of purchase and dealer's stamp) to the appro-
priate Service Centre.
Repair service:
Please ask your nearest service centre
how to proceed for repairing faults not
covered by the warranty or occurring
after the warranty expires.
10
Technical specifications
Dimensions (H x W x D):
88 x 230 x 145 mm (L 800 LED iHF)
91 x 230 x 145 mm (L 810 LED iHF)
260 x 230 x 145 mm (L 820 LED iHF)
Material:
Light enclosure:
Designer trim panel:
Power supply:
230 – 240 V, 50 Hz
Output:
10 W LEDs / 440 lm / 44 lm/W (L 800 LED iHF)
12.5 W LEDs / 612 lm / 49 lm/W (L 810 LED iHF)
12.5 W LEDs / 612 lm / 49 lm/W (L 820 LED iHF)
Colour temperature:
3000 kelvin (warm white)
LED life expectancy:
50,000 hours
Detection angle:
160° with sneak-by guard
Detection reach:
1 – 5 m (radially)
Twilight setting:
2 – 2000 lux
Time setting:
5 sec. – 15 min.
Basic lighting level:
0 or 10%, soft start
Manual override:
selectable (4 hours)
IP rating:
IP 44
Protection class:
II
Temperature range:
- 20 °C to + 50 °C

Troubleshooting

Malfunction
Cause
n Fuse faulty, not switched ON,
SensorLight without power
break in wiring
n Short circuit
n Twilight setting in night-time
SensorLight will not switch ON
mode during daytime
n Mains power switch OFF
n Fuse faulty
n Detection zone not properly
targeted
n Continued movement in the
SensorLight will not switch OFF
detection zone
n Basic lighting level selected
SensorLight will not switch OFF
completely
n Wind is moving trees and
SensorLight switching ON
when it should not
bushes in the detection zone
n Cars in the street are detected
plastic
aluminium
Remedy
n New fuse, turn on power switch,
check wiring with voltage tester
n Check connections
n Reset (control dial
)
n Switch ON
n Fit new fuse, check connection
if necessary
n Re-adjust
n Check detection zone and
re-adjust if necessary
n Turn programme selector
dial to 0
n Change zone
n Change zone